Notice of Intent
Inhalational Anaesthesia Systems - Part 4: Anaesthetic...
IEC 60601-1:1988, Clause 1 applies except as follows. Addition: This part of ISO 8835 specifies particular requirements for the essential performance of anaesthetic vapour delivery devices (AVDDs), as defined in 3.1. This...
Notice of Intent
Inhalational Anaesthesia Systems - Part 5: Anaesthetic...
IEC 60601-1:1988, Clause 1 applies except as follows: This part of ISO 8835 specifies particular requirements for the essential performance of anaesthetic ventilators (as defined in 3.1). This part of ISO 8835 is applicable...
Notice of Intent
Lighting Systems Equipment
This Standard applies to lighting systems equipment, either factory or field-assembled, rated at 600 V or less, designed to be used in non-hazardous locations, which may be smart enabled, designed to control various loads...
Notice of Intent
Braking Performance - Rubber-Tired, Self-Propelled...
1.1 This Standard describes minimum performance criteria for the service braking system, secondary braking system, and parking system for rubber-tired, self-propelled underground mining machines with maximum rated speeds of...
Notice of Intent
Explosive atmospheres - Part 28: Protection of...
This Standard specifies the requirements, testing and marking of equipment emitting optical radiation intended for use in explosive atmospheres. It also covers equipment located outside the explosive atmosphere or protected...
Notice of Intent
Safety requirements for electrical equipment ...
This clause of Part 1 is applicable except as follows: 1. Scope Replacement: This Part 2 is applicable to electrically powered LABORATORY CENTRIFUGES. NOTE If all or part of the equipment falls within the scope of one or more...
Notice of Intent
Type TECK 90 cable
Scope 1.1 This Standard applies to single- and multi-conductor Type TECK 90 armoured cable intended for installation in accordance with the Canadian Electrical Code, Part I, on systems having nominal voltages of 5000 V and...
Notice of Intent
Insulating Glass Units
1.1 This standard applies to sealed insulating glass (IG) units used in windows, doors and curtain walls in building envelopes. It includes requirements for the testing of samples for the integrity and durability of the unit...
Notice of Intent
Wired Safety Glass
1.1 This standard applies to flat rolled glass having a layer of meshed wire completely imbedded in the sheet, intended for use in skylights and general glazing in building construction where fire retardation, security and...
Notice of Intent
Plastic Safety Glazing Sheets
1.1 This standard applies to flat rigid plastic sheeting intended to provide a safe type glazing material in building construction. It shall be manufactured to prevent or reduce the likelihood of injury to persons by plastic...
Notice of Intent
Structural Design of Glass for Buildings
1.1 This standard describes the procedures recommended for the structural design of soda-lime glass for use in buildings including windows, glass doors, balustrades, partitions and sloped glazing. 1.2 This standard does not...
Notice of Intent
Performance Standard for Dusk-to-Dawn Luminaires
1. Scope 1.1 This Standard applies to luminaires, traditionally known as dusk-to-dawn luminaires or area security lights, for use in non-hazardous locations that are intended for installation outdoors on branch circuits of...