Protection contre la corrosion des structures en acier par systèmes de peinture — Évaluation et crit...
L'ISO 16276-1:2007 spécifie des modes opératoires permettant d'évaluer la résistance à la rupture d'un système de peinture, quelle que soit son épaisseur, appliqué sur un subjectile en acier ayant une épaisseur au moins égale à 10 mm. Les modes opératoires figurant dans l'ISO 16276-1:2007 reposent sur des méthodes d'essai utilisant différents types de machines d'…
Environmental solid matrices — Determination of elements using inductively coupled plasma mass spect...
This document specifies a method for the determination of the following elements in aqua regia, nitric acid or mixture of hydrochloric (HCl), nitric (HNO3) and tetrafluoroboric (HBF4)/hydrofluoric (HF) acid digests of soil, treated biowaste, waste, sludge and sediment using inductively coupled plasma mass spectrometry (ICP-MS):
Aluminium (Al), antimony (Sb), arsenic (As), barium (Ba), beryllium (…
Information technology — Spatial Reference Model (SRM)
ISO/IEC 18026:2009 specifies the Spatial Reference Model (SRM) defining relevant aspects of spatial positioning and related information processing. The SRM allows precise and unambiguous specification of geometric properties such as position (location), direction, and distance. The SRM addresses the needs of a broad community of users, who have a range of accuracy and performance requirements in…
Space systems — Failure reporting, analysis and corrective action (FRACA) process requirements
This project proposes the development of a new International Standard that defines Failure Reporting, Analysis, and Corrective Action (FRACA) process requirements. This new International Standard will require an organization, group, or individual to apply a closed-loop FRACA process that is capable of effectively managing the failure risks and issues associated with its products. In addition,…
Sludge recovery, recycling, treatment and disposal — Determination of calorific value of sludge
This Document specifies a method for the determination of the gross calorific value of sludge at
constant volume and at the reference temperature 25 °C in a bomb calorimeter calibrated by
combustion of certified benzoic acid.
The result obtained is the gross calorific value of the sample at constant volume with both the water of
the combustion products and the moisture of the sludge as liquid…
Containment high efficiency filtration unit (CHEFU) in ventilation system of biosafety facilities
This document specifies terms and definitions, classification and marking, materials, requirements, test methods, inspection rules as well as marking, packaging, transport and storage of exhaust high efficiency filtration unit(EFU)used in risky biosafety facilities.
This document is applicable to EFU used to remove harmful bio-aerosol in biosafety facilities. Reference may be made to this…