Biological evaluation of medical devices - Part 2: Animal welfare requirements
This National Standard of Canada is equivalent to International Standard ISO 10993-2:1992.
1 Scope
This part of ISO 10993 specifies minimum requirements for the use of animals in
biological testing.
This part of ISO 10993 is also intended
a) to establish guidelines which allow the scientist to respect life in
general;
b) to reduce the number of animal experiments and the number…
1 Scope
1.1 This Standard applies to electric household dishwashers intended to be
used in nonhazardous locations in accordance with the Canadian Electrical Code,
Part I (CEC), and the (US) National Electrical Code (NEC), on circuits having a
nominal voltage not exceeding 250 V.
Note: Wherever practical, for convenience, the term "appliance" has been used
in lieu of dishwasher or…
1 Scope
1.1 This Standard applies to electric clothes washing machines and extractors
intended to be used in nonhazardous locations in accordance with the Canadian
Electrical Code, Part I (CEC), and the (U.S.) National Electrical Code (NEC),
on circuits having a nominal voltage not exceeding 600 V.
Note: Wherever practical, for convenience, the term "appliance" has been used
in lieu…
Gas-Fired, Work Activated Air-Conditioning and Heat Pump Appliances (Internal Combustion)
1.1 SCOPE
1.1.1 This standard applies to newly produced, gas-fired, work activated, air
conditioning and heat pumping appliances, hereinafter referred to as
appliances, constructed entirely of new, unused parts and materials, which are
designed to supply conditioned air; heated and/or cooled liquid; or
refrigerants, gases, solids, or liquids to spaces remote from or adjacent to
the…
Information technology - Open Systems Interconnection - Systems Management: Metric objects and attri...
This National Standard of Canada is equivalent to International Standard ISO/IEC 10164-11:1994.
1 Scope
This Recommendation | International Standard defines the metric objects and
attributes function. The metric objects and attributes function is a systems
management function which may be used by an application process in a
centralised or decentralised management environment to…
Information technology - Open Systems Interconnection - Network layer security protocol
This National Standard of Canada is equivalent to International Standard ISO/IEC 11577:1995.
1 Scope
This ITU-T Recommendation | International Standard specifies a protocol to be
used by End Systems and Intermediate Systems in order to provide security
services in the Network layer, which is defined by CCITT Rec. X.213 | ISO/IEc
8348, and ISO 8648. The protocol defined in this ITU-T…
Gas-Fired Heat Activated Air Conditioning and Heat Pump Appliances
1.1 SCOPE
1.1.1 This standard applies to newly produced, gas-fired, heat activated, air
conditioning and heat pumping appliances, hereinafter referred to as
appliances, constructed entirely of new, unused parts and materials, which are
designed to supply conditioned air; heated and/or cooled liquid; or
refrigerants, gases, solids, or liquids to spaces remote from or adjacent to
the…
Automatic Vent Damper Devices for Use with Gas-Fired Appliances
1.1 SCOPE
1.1.1 This standard applies to the construction, performance and installation
procedures for a newly produced automatic vent damper device (herein after
referred to as device) constructed entirely of new, unused parts and materials
and designed to form a section of the vent connector from an individually,
automatically operated, gas-fired appliance equipped with a draft hood(s)…
Anaesthesia and respitory care alarm signals - Part 1: Visual alarm signals
This National Standard of Canada is equivalent to International Standard ISO 9703-1:1992.
1 Scope
This part of ISO 9703 specifies the characteristics of visual alarm signals
intended for use in anaesthesia and respiratory care. It takes into account
the recommendations of IEC 73¹).
It does not specify:
a) the medical devices on which alarms are provided;
b) the conditions that…
Anaethesia and respiratory care alarm signals - Part 2: Auditory alarm
signals
This National Standard of Canada is equivalent to International Standard ISo
9703-2:1994.
1 Scope
This part of ISO 9703 specifies the characteristics of the auditory component
of electrically generated primary alarm systems in anaesthesia and respiratory
care, either individually or as part of a centralized system. It applies only
if a particular International Standard for a medical…