1.1
This standard applies to three grades of kerosine type aviation turbine fuel
consisting entirely of hydrocarbon compounds, except as otherwise specified.
1.2
Grades JET A and JET A-1 describe fuels normally used in commercial operations.
Grade F-34 describes a fuel used within the NATO armed forces.
1.3
Jet A is suitable for summer use (May 1 - October 31) without operational…
1.1
This standard applies to two grades of wide cut type aviation turbine fuel
consisting entirely of hydrocarbon compounds except as otherwise specified.
1.2
Grade JET B describes a fuel normally used in commercial operations. Grade F-40
describes a fuel used within the NATO armed forces.
1.1
This Standard applies to connectors for use with copper or aluminum conductors,
or both, for providing contacts between current-carrying parts such as
terminals, between lengths of wire and tap connectors, in accordance with the
Canadian Electrical Code, Part I, as follows:
(a) pressure wire connectors intended to hold one or more copper or
aluminum conductor(s);
(b) connectors…
1. Scope
1.1
This Standard applies to corrugated electrical nonmetallic tubing (ENT),
couplings, and fittings into which it is intended that conductors be drawn, for
use in accordance with the Rules of the Canadian Electrical Code, Part I, in
nonhazardous locations.
1.2
This Standard applies to products that are intended for a maximum continuous
operating temperature of 75 degrees C…
Recommended Practices for Electrical Protection - Electric Contact BetweenOverhead Supply and Commun...
1.1
This Standard outlines the principles and general practices of electrical
protection applicable to overhead supply systems operating at more than 750 v
but less than 50 kV phase to phase and communication systems, where the lines
of those systems are located so that inadvertent electric contact between them
could occur, resulting in a contact voltage not exceeding a limit agreed to by…
1.1
This Standard applies to plumbing supply fittings of NPS-1 nominal size and
smaller, and plumbing waste fittings of NPS-2 nominal size and smaller. These
devices include but are not limited to, the following:
(a) bath and/or shower supply fittings;
(b) bidet supply fittings;
(c) clothes washer supply fittings;
(d) drinking fountain supply fittings;
(e) laundry tub supply…
1.1
This Standard sets forth the definition of Portland cement; the chemical,
physical, and uniformity requirements; the tests required; the procedures for
inspection and sampling; the units of measurement, packaging, marking, and
storage; the methods for chemical analysis and methods for physical testing;
and the equipment and materials used in performing the required tests.
1.2
The…
1.1 General
This Standard sets forth the requirements for cement prepared specifically for
use in masonry mortars.*
*Masonry cement is also sold under other names: Mortar
Cement, Mortar Mix (Unsanded), Masons Cement, Brick Cement, White Mortar
Cement, etc.
1.2 Classification of Masonry Cement
1.2.1 Type n
For use in the preparation of Type N masonry mortar, or with the use of…
1.1 Scope
This Standard sets forth the definition of blended hydraulic cement; its
chemical and physical requirements; the tests required; the procedures for
inspection and sampling; the units of measurement; the packaging, marking, and
storage; the methods for chemical analysis; the methods for physical testing;
and the equipment and materials used in performing the required tests. The…