Standard for Temporary Lighting Strings
"This standard covers temporary lighting strings rated not more than 20 A, 125 V, intended for indoor and outdoor use to provide illumination during construction, repair, or demolition of buildings or structures, or similar...
Notice of Intent
Fire Test for Heat and Visible Smoke Release ...
"This is a fire test method for determining the fire performance response of discrete products (electrical equipment) intended to be installed in air handling spaces, such as above suspended ceilings. These products are...
Notice of Intent
Standard for Mineral Fibre Thermal Insulation...
This Standard applies to mineral fibre thermal insulation manufactured in the form of faced and unfaced batts, rolls and boards. Where facings are used, they shall be either permeable or vapour retarding membranes, as defined...
Notice of Intent
Standard on Batteries for Use in Light Electric...
1 Scope 1.1 These requirements cover electrical energy storage assemblies (EESAs) such as battery packs and combination battery pack-electrochemical capacitor assemblies and the subassembly/modules that make up these...
Notice of Intent
Standard for Flexible Underground Hose Connectors...
1 SCOPE 1.1 This Standard sets forth requirements for flexible underground hose connectors intended for flammable and combustible liquid service at temperatures within the range of -40 °C to +50 °C. 1.2 This Standard also...
Notice of Intent
Standard for Emergency Breakaway Fittings for...
1 SCOPE 1.1 These requirements cover emergency breakaway fittings intended only for flammable and combustible liquid service including gasoline with up to 15 % ethanol. 1.2 An emergency breakaway fitting is intended for use...
Notice of Intent
Standard for Installation of Fire Alarm System
1.1 This Standard describes the requirements for the design and installation of a fire alarm system with or without voice communication capability, as defined in Section 3, Glossary. NOTE 1: This Standard is intended to apply...
Notice of Intent
Standard for Manual Stations for Fire Alarm Systems...
1.1 This Standard covers manual stations and their accessories for installation in ordinary locations, indoor and outdoor, for use in fire alarm systems. 1.2 A manual station having a pre-wound signalling mechanism and...
Notice of Intent
Standard for Factory-Built Type A Chimneys
These requirements apply to Factory-Built Type 'A' Chimneys, which do not require field fabrication. They are for use with gas and liquid fuel-fired residential appliances and building heating equipment, where the appliance...
Notice of Intent
Standard for Low Temperature Vents Type L and...
These requirements cover the design and construction of Type L vents intended for the venting of flue gases having temperatures not exceeding 300 °C. They may also be used where Type B gas vents are used. They are intended...
Notice of Intent
Standard for 650 ˚C Factory-Built Chimneys
These Requirements apply to Factory-Built Chimney assemblies which do not require field fabrication. They are for use with gas, liquid and solid fuel-fired residential appliances and building heating equipment, where the flue...
Notice of Intent
Standard for Lining Systems for Existing Masonry...
This Standard covers lining systems for existing masonry chimneys, which may or may not incorporate a liner of fire clay tile, or factory built chimneys and vents. Lining systems are classed as follows: Class 1 -- For the...