Notice of Intent

Burglary Resistant Safes 

1.1 These requirements cober burglary-resistant safes classified as follows: A Tested on Six Sides: (i) Residential Safe; (ii) Tool Resistant Safe - Class TL-15X6; (iii) Tool Resistant Safe - Class TL-30X6; (iv) Torch and...
Notice of Intent

Standard for Leakage Rated Dampers for Use in...

1.1 These requirements cover dampers intended for use in heating, ventilating and air conditioning (HVAC) systems. 1.2 Leakage-rated dampers (smoke dampers) are intended to restrict the spread of smoke in HVAC systems that...
Notice of Intent

Standard Method of Fire Test of Ceiling Firestop...

1.1 These requirements cover the test procedure for the performance evaluation of ceiling firestop flap assemblies which may or may not be part of an air diffusion device, intended for use in fire resistive floor-ceiling and...
Notice of Intent

Burglary Resistant Electronic Combination Locks

1.1 These requirements cover burglary resistant electronic combination locks designed for attachment on doors of safes, vaults, automated banking machines, depository units, and the like, to provide a means of locking the...
Notice of Intent

Standard for Exhaust Hoods and Related Controls...

1.1 These requirements cover exhaust hoods for commercial and institutional kitchens and are intended for placement over restaurant type cooking equipment, such as ranges, broilers, deep fat fryers, grills, etc., during...
Notice of Intent

Standard for Exhaust Cleaning and Recirculation...

1.1 This Standard applies to exhaust cleaning assemblies intended primarily for use with exhaust systems for commercial and institutional type cooking equipment such as ranges, broilers, deep fat fryers, grills, etc… that are...
Notice of Intent

Standard for Factory-Built Grease Ducts

1.1 These requirements cover factory-built grease ducts and grease duct assemblies that are intended to be installed as alternatives to the grease ducts constructed of all welded 1.37 mm carbon steel or 1.09 mm stainless...
Notice of Intent

Standard for Air Barrier Assemblies - Specification

1.1 This standard sets out criteria for specification of air barrier assemblies that may be used in design specification documents or in manufacturer’s product literature. 1.2 This standard provides the requirements and test...
Notice of Intent

Standard for Power Supplies for Burglar Alarm...

This Standard does not apply to power supplies that are an integral part of equipment contained in the following Standards: A Central and Monitoring Station Burglar Alarm Systems, CAN/ULC-S301; B Installation and...