CAN/CSA-Z902:20
1 Scope
1.1
This Standard provides management requirements for facilities that collect, process, store, and use human blood components for transfusion. It addresses issues of safety, efficacy, and quality for recipients, safety of donors, management of blood components, and safety of facility personnel and others who are exposed to or potentially affected by blood components.
1.2
This Standard applies to blood centres, transfusion services, and to any other organization that collects, processes, stores, or uses human blood components for transfusion.
1.3
It also includes requirements for the storage and use of blood products, when such products are within the responsibility of an organization that is covered by this Standard.
Note: While this Standard does not specifically apply to organizations that manage blood products but not blood components (e.g., a hospital pharmacy), these organizations are encouraged to review the relevant requirements for blood products and incorporate them as appropriate into their procedures.
1.4
As a management standard, this Standard is not intended to replace detailed specifications and operating procedures; rather, it is intended for use in their preparation. It includes requirements for policies and procedures, quality management, personnel, physical plant, and equipment. In addition, this Standard outlines specific requirements to be included in the facility’s operating procedures for the following activities:
a)
donor selection for allogeneic blood collection;
b)
collection of blood components for transfusion;
c)
preparation of blood components;
d)
testing and labelling of blood components;
e)
release, storage, packing, and transportation;
f)
requests, pre-transfusion testing, selection of components, and acceptance criteria;
g)
transfusion;
h)
autologous blood collection and transfusion;
i)
apheresis donation;
j)
transfusion service responsibilities regarding blood products used in the facility;
Note: This Item refers to blood products that are managed directly through the transfusion service, as opposed to those managed by other services, e.g., the pharmacy.
k)
directed donations and designated donations;
l)
pre-assessed donor programs;
m)
home transfusion;
n)
adverse event monitoring and corrective action;
o)
removal of unsafe components and donors from the blood supply;
p)
record management; and
q)
validation and maintenance of computer systems.
1.5
This Standard does not include requirements for activities associated with
a)
the collection of plasma for use in the manufacture of plasma products; and
SDO:
CSA
Language:
English
ICS Codes:
11.100
Status:
Standard
Publish date:
2020-02-29
Standard Number: