CAN/ULC-S146:2019
1 Scope
1.1 This test method evaluates the temperature transmission performance of an encapsulation material
or assembly of materials installed over a wood substrate when the test specimen is subjected to a
standard fire exposure condition following the standard time-temperature curve as described in Section 6
(Test Conditions).
1.2 It is the intent that the encapsulation period established by this test method indicates the period of
standard fire exposure when an encapsulated structural timber element is not expected to reach
temperatures sufficient to cause charring or combustion, potentially resulting in contribution to fire severity,
and shall not be construed as having determined the fire endurance period of the encapsulation material
or assembly of materials, or of the structural timber element.
1.3 It is the intent that the encapsulation period established by this test method indicates performance
only during the fire exposure period and shall not be construed as determining suitability for use after fire
exposure.
SDO:
ULC
Language:
English
ICS Codes:
13.220.50;
91.080.20
Status:
Standard
Publish date:
2019-05-30
Standard Number:
CAN/ULC-S146:2019