CAN/CSA-C22.2 No. 61010-031:17
1.1.1 Probe assemblies included in scope
This part of IEC 61010 specifies safety requirements for hand-held and hand-manipulated probe
assemblies of the types described below, and their related accessories. These probe assemblies are for
direct electrical connection between a part and electrical test and measurement equipment. They may be
fixed to the equipment or be detachable accessories for the equipment.
a) Type A: low-voltage and high-voltage, non-attenuating probe assemblies. Non-attenuating probe
assemblies that are RATED for direct connection to voltages exceeding 30 V r.m.s., 42,4 V peak, or 60 V
d.c., but not exceeding 63 kV. They do not incorporate components which are intended to provide a
voltage divider function or a signal conditioning function, but they may contain non-attenuating
components such as fuses (see Figure 1.)
b) Type B: high-voltage attenuating or divider probe assemblies. Attenuating or divider probe assemblies
that are RATED for direct connection to secondary voltages exceeding 1 kV r.m.s. or 1,5 kV d.c. but not
exceeding 63 kV r.m.s. or d.c. The divider function may be carried out wholly within the probe assembly,
or partly within the test or measurement equipment to be used with the probe assembly (see Figure 2).
c) Type C: low-voltage attenuating or divider probe assemblies. Attenuating or divider probe assemblies
for direct connection to voltages not exceeding 1 kV r.m.s. or 1,5 kV d.c. The signal conditioning function
may be carried out wholly within the probe assembly, or partly within the test or measurement equipment
intended to be used with the probe assembly (see Figure 3).
d) Type D: low-voltage attenuating, non-attenuating or other signal conditioning probe assemblies, that
are RATED for direct connection only to voltages not exceeding 30 V r.m.s., or 42,4 V peak, or 60 V d.c.,
and are suitable for currents exceeding 8 A (see Figure 4).
1.1.2 Probe assemblies excluded from scope
This standard does not apply to current sensors within the scope of IEC 61010-2-032 (Handheld and
hand-manipulated current sensors), but may apply to their input measuring circuit leads and accessories.
SDO:
CSA
Language:
English
ICS Codes:
19.080
Status:
Standard
Publish date:
2016-12-31
Standard Number:
CAN/CSA-C22.2 No. 61010-031:17