CSA N290.3-16
1.1
This Standard applies to the containment system of existing and new water-cooled nuclear power
plants.
Notes:
1) “Existing nuclear power plants” refers to those licensed for initial operation prior to 2011.
2) The requirements for new builds and existing plants might differ. Where requirements differ for new builds
and existing plants, the difference is explicitly stated.
1.2
This Standard was written as a companion document to CSA N290.0, which outlines general
requirements for safety systems.
This Standard, with its companion document, specifies requirements for the design, qualification,
installation, operation, maintenance, inspection, and documentation of a containment system.
1.3
In this Standard, “shall” is used to express a requirement, i.e., a provision that the user is obliged to
satisfy in order to comply with the standard; “should” is used to express a recommendation or that
which is advised but not required; and “may” is used to express an option or that which is permissible
within the limits of the Standard.
Notes accompanying clauses do not include requirements or alternative requirements; the purpose of a
note accompanying a clause is to separate from the text explanatory or informative material.
Notes to tables and figures are considered part of the table or figure and may be written as
requirements.
Annexes are designated normative (mandatory) or informative (non-mandatory) to define their
application.
1.4
In this Standard, “shall be considered” or “shall consider” means that the user evaluates the impact and
documents any decisions.
Note: Examples can include no action, operating procedures, design features.
SDO:
CSA
Language:
English
ICS Codes:
27.120
Status:
Standard
Publish date:
2016-02-29
Standard Number: