CAN/CSA-C68.7-11
This Standard is based on Canadian Electricity Association (CEA) WCWG-04 (02/93), Underground
Secondary Cable (used with permission from CEA).
1 Scope
1.1
This Standard specifies requirements for 600 V copper and aluminum conductor secondary and
service-entrance cables intended primarily for operation by electrical utilities. These cables are intended for
underground installation
(a) by direct burial; or
(b) in conduit systems.
This Standard also applies to multiple-conductor cable assemblies.
Notes:
(1) The cables covered by this Standard are exposed to sunlight on terminal poles and during storage.
(2) The operation of cables complying with this Standard by other than an electrical utility can be subject to additional
requirements by an authority having jurisdiction.
1.2
This Standard applies to cables with
(a) a maximum allowable conductor temperature of 75 °C or 90 °C; and
(b) cold impact and cold bend ratings of –40 °C.
1.3
Cables rated at 75 °C are suitable for voltage regulation limited applications where ampacity
considerations are not applicable.
Cables rated at 90 °C are suitable for ampacity limited applications.
1.4
In CSA Standards, “shall” is used to express a requirement, i.e., a provision that the user is obliged to
satisfy in order to comply with the standard; “should” is used to express a recommendation or that which
is advised but not required; “may” is used to express an option or that which is permissible within the
limits of the standard; and “can” is used to express possibility or capability. Notes accompanying clauses
do not include requirements or alternative requirements; the purpose of a note accompanying a clause is
to separate from the text explanatory or informative material. Notes to tables and figures are considered
part of the table or figure and may be written as requirements. Annexes are designated normative
(mandatory) or informative (non-mandatory) to define their application.
SDO:
CSA
Language:
English
ICS Codes:
29.060.20;
29.240.20
Status:
Standard
Publish date:
2011-03-31
Standard Number:
CAN/CSA-C68.7-11