Gas Appliance Pressure Regulators
1.1 SCOPE 1.1.1 Types of Regulators. This standard applies to individual gas appliance pressure regulators, which are not a part of a combination control (see Part V, Definitions), hereinafter referred to as regulators, intended for application on individual gas appliances. This standard also applies to negative gas appliance pressure regulators (see Part V, Definitions). The performance of negative pressure regulators is covered under Part III of this standard. Compliance of a device with this standard does not imply that such device is acceptable for use on gas appliances without supplemental tests with the device applied to the particular appliance design. Components performing functions other than those of a gas appliance pressure regulator shall comply with the applicable American National Standards. 1.1.2 Types of Gases. This standard applies to regulators for operations with natural, manufactured and mixed gases, liquefied petroleum gases and LP gas-air mixtures. 1.1.3 Regulators shall be classified in accordance with their intended application with reference to inlet pressures as follows: Rated Inlet Pressure ½ psi (3.48 kPa) 2 psi (13.8 kPa) 5 psi (34.5 kPa) 1.1.4 Types of Application. This standard applies to regulators for the following general types of application: a. Main burner load application; b. Pilot burner load application; c. Main burner and pilot burner load application to control a minimum pilot flow rate of: 1. 0.15 cubic foot per hour (1.18 cm³/s), P, or 2. 0.50 cubic foot per hour (3.93 cm³/s), P; or d. Domestic range application (see 2.11). 1.1.5 Mounting Positions(s). The manufacturer shall specify one or more of the following mounting classifications (see 1.12): Upright - single position on a horizontal axis with respect to the inlet connection, as specified by the manufacturer. Horizontal - any position on a horizontal axis with respect to the inlet connection. Vertical - any position on a vertical axis with respect to the inlet connection. Limited Horizontal - any position from upright to 90 degrees (1.57 rad) from upright on a horizontal axis with respect to the inlet connection. Multipoise - any position on a horizontal, vertical or intermediate axis with respect to the inlet connection. The tests specified herein shall be conducted with the regulator mounted in the manufacturer's specified upright position, unless otherwise specified herein. If the manufacturer specifies more than one mounting position, the test in 2.8 or 3.8, as applicable, shall be conducted in each mounting position. The data from these tests shall then be analyzed to determine the mounting position which produces the minimum outlet pressure and the mounting position which produces the maximum outlet pressure, based on results observed for the minimum outlet pressure setting of the regulator. a. The tests in 2.9 or 3.9 and 2.10 or 3.10 shall be conducted in the mounting position which produces the minimum outlet pressure, as determined in 2.8 or 3.8. b. The tests in 2.9 or 3.9 and 2.10 or 3.10 shall also be conducted in the mounting position which produces the maximum outlet pressure, as determined in 2.8 or 3.8. 1.1.6 The tests specified herein shall be conducted at a room temperature of 77 ± 10°F (25 ± 5.5°C). Regulator
SDO:
CSA
Language:
English
ICS Codes:
23.060.40
Status:
Withdrawn
Publish date:
1996-07-30
Standard Number:
6.3-M95