CAN/ULC-S322-92 (R2020)
1.1 These requirements cover emergency vault ventilators and vault-ventilating
ports.
1.2 Emergency vault ventilators are primarily intended to provide fresh air to
persons locked in the vault by accident or during a robbery.
1.3 Vault-ventilating ports are intended for connection to an outside
ventilating system that provides circulating air while the vault is open.
1.4 These requirements are intended to establish burglary resistant ratings.
The ratings, based on the net working time to effect entry, are as follows:
C1-30, minimum 30 min protection
C2-60, minimum 60 min protection
C2-90, minimum 90 min protection
C3-120, minimum 2 h protection
1.5 When installed in a vault according to the manufacturer's instructions,
the products covered by these requirements do not affect the burglary
resistant rating of the vault.
1.6 These requirements do not cover protection against entry by attacks with a
burning bar (thermal lance) or explosives.
1.7 These units are intended to be installed in accordance with the provision
of the Canadian Electrical Code, C22.1. However, it is intended that
inspection authorities having jurisdiction be consulted before installation of
electrical connections.
1.8 Products covered by these requirements are intended for installation in
vaults that are used for the storage of valuables, and that are protected by
special security measures that cannot be forced using normal rescue equipment,
but require waiting for a time lock or similar device to release entrapped
individuals.