CAN/ULC-S134-92 (R1998)

Standard Method of Fire Test of Exterior Wall Assemblies
1.1 This test method enables an assessment of the fire spread characteristics of non-loadbearing exterior wall assemblies. 1.2 The test determines the comparative burning characteristics of exterior wall assemblies by evaluating the following: A Fire spread over the exterior surface; B Heat flow from the fire plume to the exterior surface; and C Fire spread within the test specimen. 1.3 This test method does not assess: A The fire performance of framing details or teatments of windows, doors or other openings that may be used in combination with the test specimen; and B The fire performance of the test specimen when exposed to the effects of an interior fire migrating through an exterior wall assembly.
SDO:
ULC
Language:
English
ICS Codes:
19.040; 13.220.50; 91.060.10
Status:
Withdrawn
Publish date:
1992-11-29
Standard Number: