CAN/ULC-S321-1991(R2016)
1.1 These requirements cover vault doors and vault modular panels (for use in
the construction of vault floors, walls and ceilings), of the type intended for
use in financial institutions, commercial, industrial and mercantile
properties, and the like, and that are relied upon to protect the contents of
enclosed spaces from burglary attack.
Note: Requirements for fire resistant rating of vaults and vault
doors are outside the scope of this Standard and should be determined
in accordance with Chapter 2 of the Supplement to the National Building
Code of Canada or in accordance with ULC/ORD-C72A, Fire Resistance of
Prefabricated Structure Supported Vaults.
1.2 These requirements are intended to establish the burglary resistant rating
of vault doors and modular panels according to the length of time they
withstand attack by common mechanical tools, electrical tools, cutting torches,
or any combination of these means in the hands of experienced operators. The
ratings based on the net working time to effect entry are as follows:
Class
C1-30 Minimum 30 min protection
C2-60 Minimum 60 min protection
C2-90 Minimum 90 min protection
C3-120 Minimum 2 h protection
1.3 These requirements do not cover attacks with the burning bar (thermal
lance) or explosives.