ISO/IEC TR 11801-9911:2024

Information technology - Generic cabling for customer premises - Part 9911: Guidelines for the use of balanced single pair applications within a balanced 4-pair cabling system
ISO/IEC TR 11801-9911:2024, which is a Technical Report, a) describes the rules of implementation of balanced single pair as described by ISO/IEC 11801-6:2017/AMD1:202x within a balanced 4- pair cabling system with a current carrying capacity of 0,75 A per conductor; b) describes the use of components and cabling to implement and configure according to ISO/IEC 11801-6:2017/AMD1:202x c) describes links and components for generic single pair channels according to ISO/IEC 11801-1:2017/AMD1:202x. Particular areas of interest are: • remote powering according to IEEE Std 802.3, Clause 104 • loop resistance, max. current • insertion loss • return loss • noise considerations • frequency range requirements (low and high) • length calculation of the SCP-Link-4-pair-cable • number of channels d) describes the use of application specific single pair channels in addition to ISO/IEC 11801:2017/AMD1:202x, 6.6.4 e) describes guidance on single pair remote powering applications when using 4-pair cabling with current carrying capacity specified f) describes guidelines for planning, administration and installation
SDO:
IEC
Language:
English
ICS Codes:
35.200
Status:
Published
Publish date:
2024-11-04
Standard Number:
ISO/IEC TR 11801-9911:2024