Energy Monitoring Equipment

Designation Number:
ANSI/CAN/UL 2808
Standard Type:
National Standard of Canada - Domestic
Standard Development Activity:
Amendment Revision
ICS code(s):
17.220.20; 29.180
Status:
Proceeding to development
SDO Comment Period Start Date:
SDO Comment Period End Date:
Posted On:

Scope:

Scope

1 Scope 1.1 These requirements cover submetering equipment and open and enclosed type current sensors intended for factory or field installation within the wiring space of enclosures for switches or overcurrent devices. Installation is in accordance with the National Electrical Code, ANSI/NFPA 70 and the Canadian Electrical Code (CE Code), CSA C22.1. These requirements also cover "Service Entrance" enclosed-type current sensors intended for indoor and outdoor use. 1.2 These current sensors are rated for use in a maximum 250 V, 600 V, or 1000 V line-to-line circuit or in a maximum 1500 Vdc circuit. The frequency measurement capability of the sensors is governed by the stated frequency. 1.3 Current sensor conductor leads under the scope of this standard are considered a Class 1 circuit, as defined by the National Electrical Code, ANSI/NFPA 70, and the Canadian Electrical Code (CE Code), CSA C22.1 and are intended to be installed with NFPA 70 Chapter 3, wiring methods and CE Code Section 12, wiring methods. 1.4 This standard does not include investigation of the function of the controlled equipment. 1.5 These current sensors have not been evaluated for accuracy or use with emergency control systems where the function of the control could affect safety. 1.6 These current sensors are intended for use in an ambient temperature of 0 – 40°C (32 – 104°F) unless specifically indicated for use in other conditions. 1.7 These current sensors are intended for use at altitudes up to 2000 m (6562 ft) and in a humidity tolerance of 0 – 95 percent, unless indicated for use in other conditions. 1.8 Unless specifically evaluated and marked “Service Entrance”, these current sensors are evaluated for installation within equipment on the load side of the service equipment overcurrent device.

Project need:

Project Need
Changes to ANSI/CAN/UL 2808 are being proposed to update Current Sensors Construction, Signal Gathering/Multiplexer Accessories, and Submetering Equipment.

Note: The information provided above was obtained by the Standards Council of Canada (SCC) and is provided as part of a centralized, transparent notification system for new standards development. The system allows SCC-accredited Standards Development Organizations (SDOs), and members of the public, to be informed of new work in Canadian standards development, and allows SCC-accredited SDOs to identify and resolve potential duplication of standards and effort.

Individual SDOs are responsible for the content and accuracy of the information presented here. The text is presented in the language in which it was provided to SCC.