Standard for Safety for Meters for Flammable and Combustible Liquids and LP-Gas

Designation Number:
ANSI/CAN/UL/ULC 25
Standard Type:
National Standard of Canada - Domestic
Standard Development Activity:
New Standard
ICS code(s):
17.120.01; 75.180.30
Status:
Proceeding to development
SDO Comment Period Start Date:
SDO Comment Period End Date:
Posted On:

Scope:

Scope

1.1   These requirements cover:

a)  Meters for flammable and combustible liquids, of the type and size commonly used in the assembly of motor fuel dispensing devices; and

b)  Meters for liquefied petroleum gas (LP-Gas), of the type and size commonly used in the assembly of motor fuel dispensing devices and tank trucks.

The meters are of the positive liquid displacement type.

NOTE: For the purposes of this standard the terms “LP-Gas” and “Propane” are interchangeable.

1.2   Flammable and Combustible Liquids shall be handled at pressures not exceeding 50 psi (350 kPa) and at temperatures within the range of -29 °C (-20 °F) to 52 °C (125 °F).

1.3   Products covered by this Standard are intended to be installed and used in accordance with the applicable Codes and Regulations as determined by the Authority Having Jurisdiction (AHJ), such as, but not limited to:

In the United States:

a)  Flammable and Combustible Liquids Code, NFPA 30;

b)  Code for Motor Fuel Dispensing Facilities and Repair Garages, NFPA 30A; and

c)  Liquefied Petroleum Gas Code, NFPA 58.

In Canada:

a)  The Canadian Electrical Code;

b)  The National Fire Code of Canada;

c)  Natural gas and propane installation code, CSA B149.1;

d)  Propane storage and handling code, CSA B149.2; and

e)  Provincial or other Regulations.

1.4   These requirements do not cover:

a)  Meters for use with liquefied petroleum gas in the gaseous phase;

b)  Velocity meters, head meters, or area meters;

c)  Meters for use in centralized fuel oil distribution systems; and

d)  Meter components incorporating electrical circuits except those meeting intrinsically safe or explosion standards.

1.5   Determinations of the suitability of registers, counters, or computers used or provided with these meters, or the accuracy of measurement resulting from or required in actual application are not within the scope of these requirements.

1.6   Determinations of the suitability of registers, counters, or computers used or provided with these meters, or the accuracy of measurement resulting from or required in actual application are not within the scope of these requirements.

1.7   For requirements for meters for biodiesel fuel, diesel/biodiesel blends with nominal biodiesel concentrations up to 20 % (B20), refer to the Standard Meters for Diesel Fuel, Biodiesel Fuel, Diesel/Biodiesel Blends with Nominal Biodiesel Concentrations up to 20 Percent (B20), Kerosene, and Fuel Oil, UL 25B for additional requirements.

1.8   For requirements for meters for biodiesel fuel, diesel/biodiesel blends with nominal biodiesel concentrations up to 20 % (B20), refer to the Standard Meters for Diesel Fuel, Biodiesel Fuel, Diesel/Biodiesel Blends with Nominal Biodiesel Concentrations up to 20 Percent (B20), Kerosene, and Fuel Oil, UL 25B for additional requirements.

Project need:

Project Need
This standard is being proposed to develop a harmonized joint US-Canada Standard that uses UL 25 as the seed document and merges relevant content from ULC/ORD-C25 into a single new document: ANSI/CAN/UL/ULC 25.

Note: The information provided above was obtained by the Standards Council of Canada (SCC) and is provided as part of a centralized, transparent notification system for new standards development. The system allows SCC-accredited Standards Development Organizations (SDOs), and members of the public, to be informed of new work in Canadian standards development, and allows SCC-accredited SDOs to identify and resolve potential duplication of standards and effort.