Standard Method of Fire Test of Exterior Wall Assemblies
Scope:
This test method evaluates the performance of an exterior wall assembly under controlled conditions representing the fire exposure resulting from a post flashover fire in a compartment venting through an opening in the wall. The results may not reflect the actual performance of an exterior wall assembly under all fire exposure conditions.
The test determines the comparative burning characteristics of exterior wall assemblies by evaluating the following:
A Fire spread over the exterior surface;
B Heat flow from the fire plume to the exterior surface; and
C Fire spread within the test specimen.
This test method does not assess:
A The fire performance of framing details or treatments of windows, doors or other openings that may be used in combination with the test specimen;
B The fire performance of the test specimen when exposed to the effects of an interior fire migrating through an exterior wall assembly; and
C Loadbearing capabilities of the exterior wall.
Project need:
Note: The information provided above was obtained by the Standards Council of Canada (SCC) and is provided as part of a centralized, transparent notification system for new standards development. The system allows SCC-accredited Standards Development Organizations (SDOs), and members of the public, to be informed of new work in Canadian standards development, and allows SCC-accredited SDOs to identify and resolve potential duplication of standards and effort.
Individual SDOs are responsible for the content and accuracy of the information presented here. The text is presented in the language in which it was provided to SCC.