Wood Preservation
Scope:
Note: This notice of intent was withdrawn by the responsible SDO on March 5, 2024.
CSA O80.0:21 - General requirements for wood preservation
Scope
1.1
The CSA O80 Series of Standards specifies requirements related to the preservation and fire retardance of wood through chemical treatment (pressure and thermal impregnation). The subjects covered include materials and their analysis, pressure and thermal impregnation procedures, and fabrication and installation to put treated wood into service.
1.2
This Standard lists reference publications and provides definitions applicable to the entire CSA O80 Series of Standards. This Standard also describes how the CSA O80 Series of Standards differs from related AWPA Standards and addresses the need for preservative registration. Recommendations on the use of the CSA O80 Series of Standards and related AWPA Standards can be found in Annex A.
Note: In Canada, preservative registration is carried out through Health Canada’s Pest Management Regulatory Agency.
1.3
The requirements and recommendations of the CSA O80 Series of Standards are based solely on the treatment efficacy of the chemicals in question. The CSA O80 Series of Standards does not necessarily take all laws and regulations into account.
Note: It is the responsibility of the users of the CSA O80 Series of Standards to ensure that their use of preservatives does not conflict with applicable laws and regulations.
1.4
In this Standard, shall is used to express a requirement, i.e., a provision that the user is obliged to satisfy in order to comply with the standard; should is used to express a recommendation or that which is advised but not required; and may is used to express an option or that which is permissible within the limits of the Standard.
Notes accompanying clauses do not include requirements or alternative requirements; the purpose of a note accompanying a clause is to separate from the text explanatory or informative material.
Notes to tables and figures are considered part of the table or figure and may be written as requirements.
Annexes are designated normative (mandatory) or informative (non-mandatory) to define their application.
--------------------------------------------------------------------------------------------------------------------------------
CSA O80.1:21 - Specification of treated wood
Scope
1.1
This Standard is intended to help specifiers identify appropriate requirements for specific wood products and end use environments.
Note: The existence of a particular requirement in this Standard does not imply that the permitted combination of preservatives, processes, and/or wood species will be recognized by a regulatory body.
1.2
In this Standard, shall is used to express a requirement, i.e., a provision that the user is obliged to satisfy in order to comply with the standard; should is used to express a recommendation or that which is advised but not required; and may is used to express an option or that which is permissible within the limits of the Standard.
Notes accompanying clauses do not include requirements or alternative requirements; the purpose of a note accompanying a clause is to separate from the text explanatory or informative material.
Notes to tables and figures are considered part of the table or figure and may be written as requirements.
Annexes are designated normative (mandatory) or informative (non-mandatory) to define their application.
--------------------------------------------------------------------------------------------------------------------------------
CSA O80.2:21 - Processing and treatment
Scope
1.1
This Standard specifies minimum requirements for treatment of wood products covered by the CSA O80 Series of Standards, including conditioning for treatment, treatment processes and limitations, end results of treatment, post-treatment handling, and quality control. Treatment practices and results should comply with the CSA O80 Series of Standards as a whole and, subject to Clause 4of CSA O80.0, the relevant AWPA Standards.
1.2
In this Standard, shall is used to express a requirement, i.e., a provision that the user is obliged to satisfy in order to comply with the standard; should is used to express a recommendation or that which is advised but not required; and may is used to express an option or that which is permissible within the limits of the Standard.
Notes accompanying clauses do not include requirements or alternative requirements; the purpose of a note accompanying a clause is to separate from the text explanatory or informative material.
Notes to tables and figures are considered part of the table or figure and may be written as requirements.
Annexes are designated normative (mandatory) or informative (non-mandatory) to define their application.
--------------------------------------------------------------------------------------------------------------------------------
CSA O80.3:21 - Preservative formulations
Scope
1.1
This Standard specifies preservative requirements not referenced elsewhere.
Note: It is intended that this Standard will be used to accommodate additional preservative formulations (if any) in future editions of the CSA O80 Series of Standards.
1.2
In this Standard, shall is used to express a requirement, i.e., a provision that the user is obliged to satisfy in order to comply with the standard; should is used to express a recommendation or that which is advised but not required; and may is used to express an option or that which is permissible within the limits of the Standard.
Notes accompanying clauses do not include requirements or alternative requirements; the purpose of a note accompanying a clause is to separate from the text explanatory or informative material.
Notes to tables and figures are considered part of the table or figure and may be written as requirements.
Annexes are designated normative (mandatory) or informative (non-mandatory) to define their application.
--------------------------------------------------------------------------------------------------------------------------------
CSA O80.5:21 - CCA additives — Utility poles
Scope
1.1
This Standard specifies requirements for preparation and use of CCA preservative/additive combinations for utility poles permitted by CSA O80.1 and CSA O80.2.
1.2
In this Standard, shall is used to express a requirement, i.e., a provision that the user is obliged to satisfy in order to comply with the standard; should is used to express a recommendation or that which is advised but not required; and may is used to express an option or that which is permissible within the limits of the Standard.
Notes accompanying clauses do not include requirements or alternative requirements; the purpose of a note accompanying a clause is to separate from the text explanatory or informative material.
Notes to tables and figures are considered part of the table or figure and may be written as requirements.
Annexes are designated normative (mandatory) or informative (non-mandatory) to define their application.
Project need:
Note: The information provided above was obtained by the Standards Council of Canada (SCC) and is provided as part of a centralized, transparent notification system for new standards development. The system allows SCC-accredited Standards Development Organizations (SDOs), and members of the public, to be informed of new work in Canadian standards development, and allows SCC-accredited SDOs to identify and resolve potential duplication of standards and effort.
Individual SDOs are responsible for the content and accuracy of the information presented here. The text is presented in the language in which it was provided to SCC.