Window, door, and skylight installation

Logo
CSA Group
Standards Development Organisation:
Working Program:
Designation Number:
CSA A440.4:19
Standard Type:
National Standard of Canada - Domestic
Standard Development Activity:
Reaffirmation
ICS code(s):
91.060.50
Status:
Proceeding to development
SDO Comment Period Start Date:
SDO Comment Period End Date:
Posted On:

Scope:

Scope

1.1

This Standard sets forth methods for both new installation and replacement installation of factory assembled windows, exterior doors, and skylights that are intended for installation in low-rise buildings and buildings used primarily for, but not limited to, residential occupancy where the windows, doors, and skylights (including window wall) are R, LC, or CW class within the application of AAMA/WDMA/CSA 101/I.S.2/A440.

 

Note: The effectiveness, safety, and durability of installed fenestration products depend on the choice and quality of materials and design, adequate assembly, the support system, and proper installation. Improper installation of fenestration products might reduce their effectiveness, including excessive condensation; unacceptably high levels of air, water, and sound leakage; and deterioration of the wall and roof systems into which they are installed.

 

1.2

This Standard provides minimum requirements for the installation of fenestration products including windows, doors, and skylights. This Standard addresses issues that could compromise the performance of the fenestration product as established by testing to the requirements of AAMA/WDMA/CSA 101/I.S.2/A440. Where installation methods are not specifically addressed in this Standard or in the installation instructions of the manufacturer of a fenestration product, a design professional should be consulted for a solution consistent with the intent of the minimum requirements and principles in this Standard.

 

1.3

Annex H introduces the issue of climate change and its associated effects on fenestration in buildings. It is anticipated that fenestration designers will need to incorporate changes in climate loads resulting from climate change into fenestration product design. It is also anticipated that adjustments will need to be made to installation detailing. Annex H provides some information on these topics for consideration by building design professionals, authorities having jurisdiction, and installers. As information on climate change evolves, so too will the requirements of this Standard.

 

The application of this Standard requires a working knowledge of applicable federal, provincial, and local (municipal) building codes and regulations specifically concerning, but not limited to, required means of egress and requirements for safety glazing.

 

1.4

This Standard does not apply to the

 

a) selection of fenestration products for a given application;

 

b) selection of other products for use in the installation;

 

c) installation of storm windows or storm doors;

 

d) maintenance of installed fenestration products;

 

e) rebuilding of fenestration products; or

 

f) fabrication of fenestration products, whether such fabrication takes place in a factory or at the installation site.

 

Note: For product selection information, see CSA A440S1.

 

1.5

This Standard does not purport to address all of the safety problems associated with its use. It does not set out requirements relating to the safety of the person installing the units. It is the responsibility of the installer to obtain necessary health and safety training and to follow proper procedures for safe handling and application of installation materials and fenestration products.

 

1.6

This Standard assumes that its users are familiar with the terminology, procedures, and requirements of good building practice. Some requirements and guidance are included in this Standard, but the installer should also refer to information available from installation material and fenestration product manufacturers.

 

1.7

This Standard does not address the qualifications and skills that an installer should possess. It assumes familiarity with the fundamentals of low-rise building construction in Canada as described in Division B, Part 9 of NBC 2015 and of installation techniques for fenestration products normally available in Canada. Although guidance is provided in the manner of installation of fenestration products, it is not a training manual.

 

1.8

In this Standard, shall is used to express a requirement, i.e., a provision that the user is obliged to satisfy in order to comply with the standard; should is used to express a recommendation or that which is advised but not required; and may is used to express an option or that which is permissible within the limits of the Standard.

 

Notes accompanying clauses do not include requirements or alternative requirements; the purpose of a note accompanying a clause is to separate from the text explanatory or informative material.

 

Notes to tables and figures are considered part of the table or figure and may be written as requirements.

 

Annexes are designated normative (mandatory) or informative (non-mandatory) to define their application.

 

1.9

The values given in SI units are the units of record for the purposes of this Standard. The values given in parentheses are for information and comparison only.

Project need:

Project Need
To review the Standard within the required 5 year period.

Note: The information provided above was obtained by the Standards Council of Canada (SCC) and is provided as part of a centralized, transparent notification system for new standards development. The system allows SCC-accredited Standards Development Organizations (SDOs), and members of the public, to be informed of new work in Canadian standards development, and allows SCC-accredited SDOs to identify and resolve potential duplication of standards and effort.

Individual SDOs are responsible for the content and accuracy of the information presented here. The text is presented in the language in which it was provided to SCC.