Thermoplastic nonpressure piping compendium

Logo
CSA Group
Standards Development Organisation:
Working Program:
Designation Number:
CSA B1800
Standard Type:
National Standard of Canada - Domestic
Standard Development Activity:
New Edition
ICS code(s):
23.040.45
Status:
Open for SDO comment
SDO Comment Period Start Date:
SDO Comment Period End Date:
Posted On:

Scope:

Scope

CSA B181.0:24 - Definitions, general requirements, and methods of testing for thermoplastic nonpressure piping

 

Scope

 

1.1 Scope of the B1800 compendium

 

This Compendium specifies requirements for compounds and for manufactured pipe and pipe fittings, the relevant test methods, and marking requirements, and applies to thermoplastic nonpressure piping including

 

a) drain, waste, and vent pipe and pipe fittings;

 

b) sewer and storm pipe and pipe fittings; and

 

c) accessories such as factory-assembled expansion joints, closet flanges, backwater valves, and cleanouts.

 

Note: This Compendium does not specify requirements for venting of combustion gases. In Canada, ULC S636 specifies testing and marking requirements for pipe, fittings, and accessories intended for venting of combustion gases. In the U.S., UL 1738 specifies testing and marking requirements for pipe, fittings, and accessories intended for venting of combustion gases.

 

1.2 Scope of this Standard

 

This Standard specifies definitions, general requirements for compounds and for manufactured pipe and pipe fittings, the relevant test methods, and marking requirements.

 

1.3 Intent of this Standard

 

This Standard is intended to be used in conjunction with one of the other Standards in the CSA B181 or CSA B182 series to form a complete Standard for a particular product.

 

1.4 Terminology

 

In this Standard, shall is used to express a requirement, i.e., a provision that the user is obliged to satisfy in order to comply with the Standard; should is used to express a recommendation or that which is advised but not required; and may is used to express an option or that which is permissible within the limits of the Standard.

 

Notes accompanying clauses do not include requirements or alternative requirements; the purpose of a note accompanying a clause is to separate from the text explanatory or informative material.

 

Notes to tables and figures are considered part of the table or figure and may be written as requirements.

 

Annexes are designated normative (mandatory) or informative (non- mandatory) to define their application.

 

------------------------------------------------------------------------------------------------------------

 

CSA B181.1:24 - Acrylonitrile-butadiene-styrene (ABS) drain, waste, and vent pipe and pipe fittings

 

Scope

 

1.1 General

 

This Standard specifies requirements for acrylonitrile-butadiene-styrene (ABS) drain, waste, and vent (DWV) pipe, pipe fittings (including push-fit fittings), and accessories such as factory-assembled expansion joints, closet flanges, and backwater valves.

 

Notes:

 

1) Recommended installation practices for ABS-DWV pipe are specified in Annex A. Use of these recommended practices can help to ensure proper installation and optimum service life.

 

2) The maximum pressure used to test DWV installations should be 100 kPa (see Clause A.5.2).

 

3) This Standard does not specify requirements for venting of combustion gases. In Canada, ULC S636 specifies testing and marking requirements for pipe, fittings, and accessories intended for venting of combustion gases. In the U.S., UL 1738 specifies testing and marking requirements for pipe, fittings, and accessories intended for venting of combustion gases.

 

------------------------------------------------------------------------------------------------------------

 

CSA B181.2:24 - Polyvinylchloride (PVC) and chlorinated polyvinylchloride (CPVC) drain, waste, and vent pipe and pipe fittings

 

Scope

 

1.1 General

 

This Standard specifies requirements for polyvinylchloride (PVC) and chlorinated polyvinylchloride (CPVC) drain, waste, and vent (DWV) pipe, pipe fittings (including push-fit fittings), and accessories such as factory-assembled expansion joints, closet flanges, backwater valves, and fire-stop fittings*.

 

* The fire stop is for use in fire separations only. It can be subject to code requirements not covered in this Standard.

 

Notes:

 

1) Recommended installation practices for PVC-DWV pipe are specified in Annex A. Following these practices will help ensure proper installation and optimum service life.

 

2) The maximum pressure used to test DWV installations should be 100 kPa (see Clause A.5.2).

 

3) This Standard does not specify requirements for venting of combustion gases. In Canada, ULC S636 specifies testing and marking requirements for pipe, fittings, and accessories intended for venting of combustion gases. In the U.S., UL 1738 specifies testing and marking requirements for pipe, fittings, and accessories intended for venting of combustion gases.

 

------------------------------------------------------------------------------------------------------------

 

CSA B181.3:24 - Polyolefin and polyvinylidene fluoride (PVDF) laboratory drainage systems

 

Scope

 

1.1 General

 

This Standard specifies requirements for compounds, pipe, and fittings used in polyolefin and polyvinylidene fluoride (PVDF) laboratory drainage systems for corrosive applications.

 

Notes:

 

1) Polyolefin includes both PE and PP plastics.

 

2) PVDF includes emulsion or suspension polymerization of vinylidene fluoride, and copolymers of vinylidene and hexafluoropropylene produced by emulsion or suspension.

 

3) Other thermoplastics may be certified to this Standard provided they comply with the requirements specified in this Standard.

 

1.2 Joining method

 

Pipe and fittings covered in this Standard are intended to be joined by heat fusion using joining equipment supplied by the manufacturer.

 

1.3 Transitioning between different manufacturers’ products

 

This Standard is not intended to provide for interchangeability between plastic pipe and fittings from different manufacturers, but it does allow for transition fittings used to join one manufacturer’s product to another’s provided the joining technique is other than heat fusion.

 

Note: See Annex A for guidance on fusion joints and aboveground and underground installations.

 

1.4 Differing or additional characteristics

 

Polyolefin laboratory drainage systems having characteristics differing from or additional to those covered by this Standard should be investigated to determine whether they comply with the intent of this Standard.

 

------------------------------------------------------------------------------------------------------------

 

CSA B181.5:24 - Coextruded acrylonitrile-butadiene- styrene/polyvinylchloride (ABS/PVC) drain, waste, and vent pipe

 

Scope

 

1.1 General

 

This Standard specifies requirements for coextruded thermoplastic drain, waste, and vent (DWV) pipe with an outer layer of acrylonitrile-butadiene-styrene (ABS) and an inner layer of polyvinylchloride (PVC), or with outer and inner layers of ABS and a core of PVC.

 

1.2 Intent of this Standard

 

Pipe manufactured in accordance with this Standard is intended to be used with fittings, accessories, and solvent cement that comply with CSA B181.1.

 

Note: Recommended storage, handling, and installation practices for coextruded ABS/PVC-DWV pipe are provided in Annex A of CSA B181.1. Use of these recommended practices can help to ensure proper installation and optimum service life.

 

------------------------------------------------------------------------------------------------------------

 

CSA B182.1:24 - Plastic drain and sewer pipe and pipe fittings

 

Scope

 

1.1 General

 

This Standard specifies requirements for

 

a) plastic drain and sewer pipe and plastic pipe fittings with pipe stiffness of 275, 320, or 625 kPa, including single-wall, coextruded, and coextruded dual-wall pipe with a smooth interior;

 

b) single-wall, non-corrugated, perforated plastic pipe and plastic pipe fittings with a pipe stiffness of 200 kPa;

 

c) coextruded dual-wall perforated plastic pipe with a smooth interior, corrugated exterior, and a pipe stiffness of 200 kPa; and

 

d) solvent cement.

 

Notes:

 

1) Industrial waste disposal lines should be installed only with the approval of the authority having jurisdiction because chemicals not commonly found in drains and sewers, and temperatures greater than 60 ° C, can be encountered.

 

2) Annex A provides guidance on the relationship between pipe stiffness and the end use of the pipe.

 

------------------------------------------------------------------------------------------------------------

 

CSA B182.2:24 - PSM type polyvinylchloride (PVC) sewer pipe and fittings

 

Scope

 

1.1 General

 

This Standard specifies requirements for SDR 26, 28, 35, and 41 PSM type polyvinylchloride (PVC) perforated and non-perforated sewer pipe and fittings.

 

Notes:

 

1) Industrial waste disposal lines should be installed only with the approval of the authority having jurisdiction because chemicals not commonly found in drains and sewers, and temperatures greater than 60 ° C, can be encountered.

 

2) Nominal pipe size is indicated by an NPS designation and actual dimensions are given in millimeters. For example, an NPS-10 pipe will be nominally 10 in in diameter.

 

1.2 Multilayer construction

 

Pipe manufactured to this Standard may have multilayer construction, and the middle layer may have reprocessed-recycled content.

 

Note: In this Standard, the term multilayer refers to pipe having three layers.

 

------------------------------------------------------------------------------------------------------------

 

CSA B182.4:24 - Profile polyvinylchloride (PVC) sewer pipe and fittings

 

Scope

 

1.1 General

 

This Standard specifies requirements for profile polyvinylchloride (PVC) sewer pipe and fittings of pipe stiffness 70 and 320 (PS70 and PS320), based on controlled inside diameter.

 

Notes:

 

1) Pipe and fittings manufactured in accordance with this Standard should be installed in accordance with CSA B182.11.

 

2) Industrial waste disposal lines should be installed only with the approval of the authority having jurisdiction because chemicals not commonly found in drains and sewers, and temperatures greater than 60 ° C, can be encountered.

 

3) When PS70 pipe is used, the appropriate authority having jurisdiction should be consulted.

 

------------------------------------------------------------------------------------------------------------

 

CSA B182.6:24 - Profile polyethylene (PE) sewer pipe and fittings for leak-proof sewer applications

 

Scope

 

1.1 General

 

This Standard specifies requirements for open profile polyethylene (PE) sewer pipe and fittings with annular corrugations for leak-proof applications (e.g., sanitary sewer and other gravity-flow applications).

 

Notes:

 

1) Pipe and fittings manufactured in accordance with this Standard should be installed in accordance with CSA B182.11.

 

2) See Annex A for recommended quality control test frequencies.

 

3) See Annex C for fitting patterns of the lay length of fittings covered by this Standard.

 

4) Annex D should be followed to ensure the requested products are described adequately.

 

------------------------------------------------------------------------------------------------------------

 

CSA B182.8:24 - Profile polyethylene (PE) storm sewer and drainage pipe and fittings

 

Scope

 

1.1 General

 

This Standard specifies requirements for open profile polyethylene (PE) storm sewer and drainage pipe and fittings with annular corrugations for gasketed and non-gasketed leak-proof applications. The products covered under this Standard may be manufactured using either virgin or recycled (post- industrial or post-consumer) materials.

 

Notes:

 

1) Pipe and fittings manufactured in accordance with this Standard should be installed in accordance with CSA B182.11.

 

2) See Annex A for recommended quality control test frequencies.

 

3) See Annex C for fitting patterns of the lay length of fittings covered by this Standard.

 

4) Annex F should be followed to ensure the requested products are described adequately.

 

5) See Annex G for additional minimum quality control test frequencies for pipes made with recycled materials.

 

1.2 Exclusions

 

This Standard does not cover 210 kPa pipe in sizes smaller than NPS-12.

 

------------------------------------------------------------------------------------------------------------

 

CSA B182.11:24 - Standard practice for the installation of thermoplastic drain, storm, and sewer pipe and fittings

 

Scope

 

1.1 General

 

This Standard specifies requirements for the installation and testing of thermoplastic and steel- reinforced PE pipes used for the conveyance of drain, storm, and sanitary effluent in gravity-flow systems.

 

Note: Users of this Standard should recognize that installation specifications cover a broad range of conditions for thermoplastic pipe. The engineer should tailor the installation specifications to special conditions and the contract documents. The documentation should specify any work or materials not covered by this Standard.

 

1.2 Applicability

 

This Standard applies to pipe manufactured in accordance with CSA B182.1, CSA B182.2, CSA B182.4, CSA B182.6, CSA B182.8, CSA B182.12, CSA B182.13, CSA B182.14, and CSA B182.15.

 

1.3 Exclusions

 

This Standard does not apply to pipe manufactured in accordance with CSA B181.1, CSA B181.2, CSA B181.3, and CSA B181.5.

 

Notes:

 

1) For the installation practice of pipe manufactured in accordance with CSA B181.1 and CSA B181.5, see Annex A of CSA B181.1.

 

2) For the installation practice of pipe manufactured in accordance with CSA B181.2, see Annex A of CSA B181.2.

 

3) For the installation practice of pipe manufactured in accordance with CSA B181.3, consult the manufacturer.

 

-----------------------------------------------------------------------------------------------------------

 

CSA B182.12:24 - Profile polypropylene (PP) storm sewer pipe and fittings

 

Scope

 

1.1 General

 

This Standard specifies requirements for open profile polypropylene (PP) storm sewer pipe and fittings for leak-proof applications.

 

Profile wall pipe includes only open profile with smooth interior and sizes based on controlled inside diameter. Open profile pipe is of an annular construction.

 

Notes:

 

1) Pipe and fittings manufactured in accordance with this Standard should be installed in accordance with CSA B182.11.

 

2) See Annex A for recommended quality control test frequencies.

 

3) See Annex B for base inside diameters.

 

4) See Annex C for fitting patterns of the lay length of fittings covered by this Standard.

 

5) See Annex D for perforation details.

 

6) Annex E should be followed to ensure the requested products are described adequately.

 

7) Appropriate structural design criteria for PP storm sewer pipe can be found in Appendix X2 of ASTM F2881/ F2881M.

 

------------------------------------------------------------------------------------------------------------

 

CSA B182.13:24 - Profile polypropylene (PP) sewer pipe and fittings for leak-proof sewer applications

 

Scope

 

1.1 General

 

This Standard specifies requirements for profile polypropylene (PP) sewer pipe and fittings for leak- proof applications (e.g., sanitary sewer and other gravity-flow applications).

 

Profile wall pipe includes both open and closed profile with smooth interiors and sizes based on controlled inside diameter. Open and closed profile pipe are both of an annular construction but not compatible or interchangeable due to structural differences in profile geometries.

 

Notes:

 

1) Pipe and fittings manufactured in accordance with this Standard should be installed in accordance with CSA B182.11.

 

2) See Annex A for recommended quality control test frequencies.

 

3) See Annex B for base inside diameters.

 

4) See Annex C for fitting patterns of the lay length of fittings covered by this Standard.

 

5) Annex D should be followed to ensure the requested products are described adequately.

 

6) Appropriate structural design criteria for PP sewer pipe can be found in ASTM F2764/F2764M.

 

-----------------------------------------------------------------------------------------------------------

 

CSA B182.14:24 - Profile steel reinforced polyethylene (SRPE) storm sewer pipe and fittings

 

Scope

 

1.1 General

 

This Standard specifies requirements for profile steel reinforced polyethylene (SRPE) sewer pipe and fittings for storm sewer, and other gravity-flow applications.

 

Profile wall pipe in this Standard includes open profile pipe of helical construction, with a smooth interior and sizes based on controlled inside diameter. The pipe can be perforated for specific applications as required.

 

Notes:

 

1) Pipe and fittings manufactured in accordance with this Standard should be installed in accordance with CSA B182.11.

 

2) The structural design of this product should be in accordance with the manufacturer’s recommendations.

 

3) See Annex A for recommended quality control test frequencies.

 

4) See Annex B for base inside diameters used to determine installation deflection limits.

 

5) See Annex C for fitting patterns covered by this Standard.

 

6) See Annex D for examples of Type 3 non-gasketed coupling joints.

 

7) The ordering recommendations in Annex E should be followed to ensure the requested products are described adequately.

 

------------------------------------------------------------------------------------------------------------

 

CSA B182.15:24 - Profile steel reinforced polyethylene (SRPE) sewer pipe and fittings

 

Scope

 

1.1 General

 

This Standard specifies requirements for profile steel reinforced polyethylene (SRPE) sewer pipe and fittings for sanitary sewer and other gravity-flow applications.

 

Profile wall pipe in this Standard includes open profile pipe of helical construction, with a smooth interior and sizes based on controlled inside diameter. The pipe can be perforated for specific applications as required.

 

Notes:

 

1) Pipe and fittings manufactured in accordance with this Standard should be installed in accordance with CSA B182.11.

 

2) The structural design of this product should be in accordance with the manufacturer’s recommendations.

 

3) See Annex A for recommended quality control test frequencies.

 

4) See Annex B for base inside diameters used to determine installation deflection limits.

 

5) See Annex C for fitting patterns covered by this Standard.

 

6) The ordering recommendations in Annex D should be followed to ensure the requested products are described adequately.

Project need:

Project Need

To update the current standard due to user experience/feedback/new technology (new edition).

 

This proposed  New Edition is being developed at the request of the B1800 technical committee. It will provide the industry with up to date performance specifications for thermoplastic nonpressure piping.

 

This will meet the strategic needs of the following key interests:

  1. ensuring that the latest innovative/technology/safety features are available for users,
  2. addressing needs of regulators by providing suitable requirements; and   
  3. supporting certification bodies.

Note: The information provided above was obtained by the Standards Council of Canada (SCC) and is provided as part of a centralized, transparent notification system for new standards development. The system allows SCC-accredited Standards Development Organizations (SDOs), and members of the public, to be informed of new work in Canadian standards development, and allows SCC-accredited SDOs to identify and resolve potential duplication of standards and effort.

Individual SDOs are responsible for the content and accuracy of the information presented here. The text is presented in the language in which it was provided to SCC.