Solid-state dimming controls
Scope:
1.1
These requirements cover permanently installed devices, hereafter referred to as dimmers, that employ a dimming function intended for control of lighting loads of the magnetic ballast, transformer, electronic ballast, self-ballasted lamp, tungsten-filament type, or light-emitting-diode (LED), and are intended to be installed in a wallbox or are provided with an enclosure for flush or surface mounting in accordance with the Canadian Electric Code, Part 1 (CEC), and the National Electrical Code (NEC), ANSI/NFPA 70.
1.2
These requirements cover dimmers, other than touch dimmers, rated 600 volts ac or less, for installation on a 20-ampere or less branch circuit.
1.3
These requirements cover touch dimmers rated 120 volts ac or less for installation on a 20-ampere or less branch circuit.
1.4 These requirements cover dimmers, including touch dimmers, and electronic switches, having a
minimum power rating of 300 watts incandescent or 300 volt-amperes in increments of 50 watts or 50
volt-amperes.
1.5 Devices may have additional current ratings based upon the additional lighting loads as specified by
the manufacturer.
1.6 A device incorporating other functions (for example, speed control) in addition to a dimming function
is investigated on the basis of compliance with the applicable requirements for the dimming function in this
Standard as well as requirements for the other functions in the applicable standards.
1.7 These requirements do not cover dimmers that use only a resistor or a transformer to perform the
dimming function.
1.8 These requirements do not cover modular, cabinet or console type constructions.
Project need:
Note: The information provided above was obtained by the Standards Council of Canada (SCC) and is provided as part of a centralized, transparent notification system for new standards development. The system allows SCC-accredited Standards Development Organizations (SDOs), and members of the public, to be informed of new work in Canadian standards development, and allows SCC-accredited SDOs to identify and resolve potential duplication of standards and effort.