Selection and installation of backflow preventers / Maintenance and field testing of backflow preventers

Logo
CSA Group
Standards Development Organisation:
Working Program:
Designation Number:
CSA B64.10/CSA B64.10.1
Standard Type:
National Standard of Canada - Domestic
Standard Development Activity:
New Edition
ICS code(s):
23.060.99
Status:
Proceeding to development
SDO Comment Period Start Date:
SDO Comment Period End Date:
Posted On:

Scope:

Scope

CSA B64.10:17 - Selection and installation of backflow preventers

Scope

1.1 Application

This Standard specifies requirements for the selection and installation of backflow preventers. Additional information on how backflow due to back siphonage and back pressure occurs, and how to select and apply specific devices, is included in Annexes A, B, and C.

1.2 Exclusions

1.2.1

This Standard does not cover

a) construction requirements or performance tests, which are covered by the CSA B64 Series;

b) plumbing supply fittings, which are covered by ASME A112.18.1/CSA B125.1;

c) plumbing fittings, which are covered by CSA B125.3; and

d) manually operated valves for use in plumbing systems, which are covered by ASME A112.4.14/ CSA B125.14.

1.2.1

This Standard does not specify requirements for materials, construction, or performance tests of backflow preventers. Such requirements are specified in the CSA B64 Series, in ASME A112.18.1/CSA B125.1, and in CSA B125.3. See Table 1.

1.2.2

This Standard does not specify requirements for maintenance or field testing after the initial installation. Such requirements are specified in CSA B64.10.1.

1.3 Terminology

In CSA standards, shall is used to express a requirement, i.e., a provision that the user is obliged to satisfy in order to comply with the standard; should is used to express a recommendation or that which is advised but not required; and may is used to express an option or that which is permissible within the limits of the standard.

Notes accompanying clauses do not include requirements or alternative requirements; the purpose of a note accompanying a clause is to separate from the text explanatory or informative material.

Notes to tables and figures are considered part of the table or figure and may be written as requirements.

Annexes are designated normative (mandatory) or informative (nonmandatory) to define their application.

1.4 Measurement

This Standard is written in SI (metric) units. For conversion tables, see Annex D. Vacuum is expressed in pressure below ambient.

------------------------------------------------------------------------------------------------------------

CSA B64.10.1:17 - Maintenance and field testing of backflow preventers

Scope

1.1

This Standard specifies requirements for the maintenance and field testing of backflow preventers.

1.2

This Standard does not specify requirements for the selection and installation of backflow preventers. Such requirements are specified in CSA B64.10.

1.3

In CSA standards, shall is used to express a requirement, i.e., a provision that the user is obliged to satisfy in order to comply with the standard; should is used to express a recommendation or that which is advised but not required; and may is used to express an option or that which is permissible within the limits of the standard.

Notes accompanying clauses do not include requirements or alternative requirements; the purpose of a note accompanying a clause is to separate from the text explanatory or informative material.

Notes to tables and figures are considered part of the table or figure and may be written as requirements.

Annexes are designated normative (mandatory) or informative (nonmandatory) to define their application.

1.4

This Standard is written in SI (metric) units. For conversion tables, see Annex D of CSA B64.10. Vacuum is expressed in pressure below ambient.

Project need:

Project Need
To update the current standard due to user experience/feedback/new technology. This proposed New Edition is being developed at the request of the B64 Technical Committee. It will provide the industry with up to date requirements for the selection and installation as well as maintenance and field testing of backflow preventers This will meet the strategic needs of the following key interests: a) ensuring that the latest innovative/technology/safety features are available for users, and b) addressing needs of regulators by providing suitable requirements.

Note: The information provided above was obtained by the Standards Council of Canada (SCC) and is provided as part of a centralized, transparent notification system for new standards development. The system allows SCC-accredited Standards Development Organizations (SDOs), and members of the public, to be informed of new work in Canadian standards development, and allows SCC-accredited SDOs to identify and resolve potential duplication of standards and effort.

Individual SDOs are responsible for the content and accuracy of the information presented here. The text is presented in the language in which it was provided to SCC.