Safety of power transformers, power supplies, reactors and similar products - Part 2-1: Particular requirements and tests for separating transformers and power supplies incorporating separating transformers for general applications

Logo
CSA Group
Standards Development Organisation:
Working Program:
Designation Number:
CSA IEC 61558-2-1
Standard Type:
National Standard of Canada - Adoption of International Standard
Standard Development Activity:
New Edition
ICS code(s):
29.180
Status:
Proceeding to development
SDO Comment Period Start Date:
SDO Comment Period End Date:
Posted On:

Scope:

Scope

Replacement:

 

This part of IEC 61558 deals with safety aspects of separating transformers and power supplies incorporating separating transformers such as electrical, thermal and mechanical safety.

 

This Part 2-1 is applicable to separating transformers and power supplies incorporating both separating transformers and electronic circuits. This Part 2-1 is not applicable to external circuits and their components intended to be connected to the input terminals, output terminals or socket-outlets of the transformers and power supplies.

 

This Part 2-1 does not apply to transformers covered by IEC 60076-11.

 

This Part 2-1 applies to stationary or portable, single-phase or polyphase, air-cooled (natural or forced) independent and associated separating transformers and power supplies, having a rated supply voltage not exceeding 1 000 V a.c., a rated supply and internal operating frequency not exceeding 500 Hz.

 

The rated output does not exceed:

 

– 1 kVA for single-phase separating transformers and single-phase power supplies incorporating separating transformers;

 

– 5 kVA for poly-phase separating transformers and poly-phase power supplies incorporating separating transformers.

 

This Part 2-1 is applicable to separating transformers and power supplies incorporating separating transformers without limitation of the rated output subject to an agreement between the purchaser and the manufacturer.

 

This Part 2-1 is applicable to dry-type transformers. The windings may be encapsulated or non-encapsulated.

 

The no-load output voltage or the rated output voltage does not exceed 1 000 V a.c. or 1 415 V ripple-free d.c. 

For independent separating transformers and independent power supplies, the no-load output voltage and / or the rated output voltage is not less than 50 V a.c., or 120 V ripple-free d.c.

 

Separating transformers covered by this Part 2-1 are used only in applications where double or reinforced insulation between circuits is not required by the installation rules or by the end product standard.

 

NOTE 1 Normally, the separating transformers and power supplies incorporating separating transformers are intended to be used with equipment to provide voltages different from the supply voltage for the functional requirements of the equipment. The protection against electric shock may be provided (or completed) by other features of the equipment, such as the body. Parts of output circuits may be connected to the input circuits or to protective earth.

 

This Part 2-1 is applicable to separating transformers and power supplies incorporating separating transformers associated with specific equipment, to the extent decided upon by the relevant IEC technical committees.

 

NOTE 2 Attention is drawn to the following:

 

– for separating transformers and power supplies incorporating separating transformers intended to be used in vehicles, on board ships, and aircraft, additional requirements (from other applicable standards, national rules, etc.) may be necessary;

 

– measures to protect the enclosure and the components inside the enclosure against external influences such as fungus, vermin, termites, solar-radiation, and icing should also be considered;

 

– the different conditions for transportation, storage, and operation of the separating transformers and power supplies incorporating separating transformers should also be considered;

 

– additional requirements in accordance with other appropriate standards and national rules may be applicable to separating transformers and power supplies incorporating separating transformers intended for use in special environments, such as tropical environment.

 

NOTE 3 Future technological development of separating transformers and power supplies incorporating separating transformers may necessitate a need to increase the upper limit of the frequencies, until then this Part 2-1 may be used as a guidance document.

 

Project need:

Project Need

To maintain alignment with international requirements new edition of IEC 61558-2-1 Edition 3.0. This proposed  New Edition is being developed at the request of CSA Certification (TIC). It will provide the industry with current international requirements.

Note: The information provided above was obtained by the Standards Council of Canada (SCC) and is provided as part of a centralized, transparent notification system for new standards development. The system allows SCC-accredited Standards Development Organizations (SDOs), and members of the public, to be informed of new work in Canadian standards development, and allows SCC-accredited SDOs to identify and resolve potential duplication of standards and effort.

Individual SDOs are responsible for the content and accuracy of the information presented here. The text is presented in the language in which it was provided to SCC.