Protection of first responders from chemical, biological, radiological, and nuclear (CBRN) events
Scope:
1.1
This Standard specifies requirements for the selection, use, and care of personal protective equipment (PPE) for first responders to a deliberate chemical, biological, radiological, or nuclear (CBRN) incident,including releases and contagious outbreak events. It is specifically targeted to fire, police, and medical first responders/receivers in the front line of the response.
1.2
This Standard covers selection, use, and care of PPE for application in the initial response and intervention phases of a CBRN event. This Standard does not directly address PPE selection for the recovery phase, where the risk to the public is reduced, the incident is contained, the nature of the hazard is well understood, and response times are not critical. For information on response phases, see Clause 4.3.
1.3
This Standard takes a systems approach in identifying the requirements for whole-body protective system performance (respiratory, ocular, and dermal), including integration with other equipment. It also provides guidance on the capabilities and limitations of CBRN PPE and on how to enhance the protection provided by, and interoperability of CBRN PPE.
1.4
This Standard does not address operational or tactical procedures for responding to a CBRN event, except where they have a direct impact on the selection of PPE.
1.5
This Standard is not intended to apply to members of the general public or to health-care-related activities other than those that would be performed by hospital first receivers prior to admission or in an emergency department or similar facility. These activities are likely to include triage, decontamination, and initial or urgent treatment, but do not include on-going care following hospital admission.
1.6
This Standard is based on the assumption that a CBRN event will include only one type of CBRN agent or, where multiple agents are present, that the protective capabilities of PPE are not affected. PPE is not evaluated for its capability to simultaneously protect against multiple types of CBRN agents; it is possible that protective capability could be degraded by particular combinations of agents. In addition, if PPE is damaged by other physical hazards, it might provide less protection, particularly if its integrity is breached.
1.7
This Standard does not address protection from the detonation phase of nuclear events; it is assumed that first responders will be exposed only to the resulting radiologically active emissions.
1.8
Equipment to protect from hazards other than CBRN is considered only in the context of integration with CBRN protection. Protection from hazards not covered by the use of PPE is not addressed in detail.
1.9
Within the Canadian legislative framework, a variety of regulations apply to the first responder (FR), depending on the jurisdiction. These should be taken into consideration when implementing this Standard.
Project need:
Note: The information provided above was obtained by the Standards Council of Canada (SCC) and is provided as part of a centralized, transparent notification system for new standards development. The system allows SCC-accredited Standards Development Organizations (SDOs), and members of the public, to be informed of new work in Canadian standards development, and allows SCC-accredited SDOs to identify and resolve potential duplication of standards and effort.
Individual SDOs are responsible for the content and accuracy of the information presented here. The text is presented in the language in which it was provided to SCC.