Outdoor Cooking Specialty Gas Appliances

Logo
CSA Group
Standards Development Organisation:
Working Program:
Designation Number:
CSA 1.18
Standard Type:
Consensus SDO Standard
Standard Development Activity:
New Edition
Status:
Proceeding to development
SDO Comment Period Start Date:
SDO Comment Period End Date:
Posted On:

Scope:

Scope

1.1
This standard applies to newly produced outdoor specialty gas appliances (see Clause 3), hereinafter referred to as appliances, constructed entirely of new, unused parts and materials. Appliances submitted for examination under this standard shall be classified as portable. These products are not intended for commercial use.

1.2
This standard applies to recreational vehicle grills (see Clauses 1.4(e) and 3) mounted to the exterior of a recreational vehicle for connection to the recreational vehicle's low pressure LP gas supply system (see Clause 1.6). It does not apply to appliances for installation in the interior living space of a recreational vehicle.

1.3
This standard does not apply to fryer/boilers and smokers for installation in or on recreational vehicles. This standard does not apply to appliances for installation in or on boats. 

1.4
An appliance may be a:
a) fryer/boiler;
b) smoker;
c) table top grill incorporating an open top broiler, top burner(s), griddle, or any combination. Table top grills shall not be a built-in type;
d) any combination of the above; or
e) recreational vehicle grill.

1.5
If a value for measurement as given in this standard is followed by an equivalent value in other units, the first stated value is to be regarded as the specification.

1.6
Appliances may be for connection to:
a) a fixed fuel piping system; or
b) a self contained liquefied petroleum gas or propane gas supply system of a single cylinder with a maximum size of 20 lb (9.1 kg) of fuel.

1.7
This standard applies to appliances operating at inlet gas pressures not to exceed ½ psi (3.5 kPa) for connection to a fixed fuel piping system:
a) for use with natural gas;
b) for use with manufactured gas;
c) for use with mixed gas;
d) for use with liquefied petroleum gases; and
e) For use with LP gas air mixtures.

1.8
This standard also applies to appliances designed for connection to self-contained LP gas and propane gas supply systems (see Clause 4.4):
a) operating at regulated outlet pressures not to exceed 1 psi (6.9 kPa); and
b) operating at regulated outlet pressures in excess of 1 psi (6.9 kPa) but not greater than 10 psi (69 kPa).

The construction of appliances for use with the above mentioned gases is covered under Clause 4.

The performance of appliances for use with the above mentioned gases is covered under Clause 5.

1.9
Throughout this document gauge pressures are designated in pounds per square inch, (psi) and kilopascals (kPa). Use of the terminology "psig" is not used. Where "psi" is used it is understood to be pound per square inch gauge. Absolute pressures are not used in this standard.

1.10
If a value for a measurement as given in this standard is followed by an equivalent value in other units, the first stated value is to be regarded as the specification. (Also, see Clause 8.)

1.11
Annex A contains the LP gas cylinder label.

1.12
Clause 7 contains provisions that are unique to the United States.

1.13
Clause 8 contains provisions that are unique to Canada. 

1.14
Clause 2 contains a list of standards specifically referenced in this standard, and sources from which these reference standards may be obtained. 

1.15
An appliance covered by this standard need not to comply with the provisions of the Standard for Gas-Fired Appliances for Outdoor Installations, CAN1-2.21.

Note: The information provided above was obtained by the Standards Council of Canada (SCC) and is provided as part of a centralized, transparent notification system for new standards development. The system allows SCC-accredited Standards Development Organizations (SDOs), and members of the public, to be informed of new work in Canadian standards development, and allows SCC-accredited SDOs to identify and resolve potential duplication of standards and effort.

Individual SDOs are responsible for the content and accuracy of the information presented here. The text is presented in the language in which it was provided to SCC.