Guideline for the application of N286.7-99, Quality assurance of analytical, scientific, and design computer programs for nuclear power plants
Scope:
1.1 This Guideline is intended to assist owner organizations and participants in the preparation and implementation of software quality assurance processes in compliance with CSA N286.7 and related requirements from CSA N286.
1.2 This Guideline is intended for those persons responsible for developing software governance and quality assurance programs and procedures.
1.3 This Guideline is intended to assist practitioners within owner and participant organizations in understanding the basis of software quality assurance processes implemented in those organizations.
1.4 This Guideline provides guidance on the development and implementation of software quality engineering procedures that reflect the current maintenance focus of software development within owner and participant organizations.
1.5 This Guideline provides guidance on the development and use of scripts, processors, and couplers, which are not included in CSA N286.7. It also provides guidance on software processes related to direct coupling of codes that were previously run in series as separate entities.
1.6 This Guideline does not apply to computer programs that are (a) used to control plant safety systems and operational control systems; (b) commercially available database management and spreadsheet programs; (c) commercially available graphics and computer-assisted drafting (CAD) programs; (d) commercially available compilers, interpreters, and computer-operating systems; and (e) commercially available mathematical libraries. Note: Items (b) and (c) include "programmed applications", which are within the scope of CSA N286.7. A graded approach to quality activities and documentation similar to that specified for scripts in Clause 15 should be used.
1.7 In this Guideline, "should" is used to express a recommendation or that which is advised but not required; "may" is used to express an option or that which is permissible within the limits of the Guideline; and "can" is used to express possibility or capability.
Note: The information provided above was obtained by the Standards Council of Canada (SCC) and is provided as part of a centralized, transparent notification system for new standards development. The system allows SCC-accredited Standards Development Organizations (SDOs), and members of the public, to be informed of new work in Canadian standards development, and allows SCC-accredited SDOs to identify and resolve potential duplication of standards and effort.
Individual SDOs are responsible for the content and accuracy of the information presented here. The text is presented in the language in which it was provided to SCC.