Gas-Fired High Intensity Infrared Heaters

Logo
CSA Group
Standards Development Organisation:
Working Program:
Designation Number:
CSA 2.35-2009
Standard Type:
Consensus SDO Standard
Standard Development Activity:
Reaffirmation
Status:
Proceeding to development
SDO Comment Period Start Date:
SDO Comment Period End Date:
Posted On:

Scope:

Scope

1.1.1 This standard applies to newly produced, gas-fired high-intensity infrared heaters (see Part IV, Definitions), hereinafter referred to as heaters or appliances, constructed entirely of new, unused parts and materials with inputs up to and including 400,000 Btu per hour (117 228 W) per burner: a. For use with natural gas; b. For use with manufactured gas; c. For use with mixed gas; d. For use with liquefied petroleum (propane) gases; e. For use with LP gas-air mixtures; or f. Convertible for use with natural gas and liquefied petroleum (propane) gases, when provision is made for the simple conversion from one gas to the other.

1.1.2 The heaters covered by this standard are intended for installation in and heating of outdoor spaces or nonresidential indoor spaces and are intended for location where flammable gases or vapors are not generally present.

Although heaters covered by this standard may, in certain instances, be suitable for application in industrial processes, this standard does not cover industrial process burners.

1.1.3 High-intensity infrared heaters may be suspended overhead, angle mounted overhead, wall mounted or floor mounted. Floor-mounted heaters may be free-standing and, when for outdoor installation, also may be portable to the extent defined in Part IV,Definitions.

1.1.4 Overhead heaters complying with this standard are suitable for use in (1) aircraft hangars when installed in accordance with the Standard for Aircraft Hangars, ANSI/NFPA 409, and (2) garages when installed in accordance with the Standard for Parking Structures, ANSI/NFPA 88A, or the Standard for Repair Garages, ANSI/NFPA 88B; or the Canadian Natural Gas and Propane Installation Code, CSA B149.1, and are so marked.

1.1.5 The heaters covered by this standard may be: a. Designed for connection to a vent; or b. Not designed for connection to a vent.

Note: The information provided above was obtained by the Standards Council of Canada (SCC) and is provided as part of a centralized, transparent notification system for new standards development. The system allows SCC-accredited Standards Development Organizations (SDOs), and members of the public, to be informed of new work in Canadian standards development, and allows SCC-accredited SDOs to identify and resolve potential duplication of standards and effort.

Individual SDOs are responsible for the content and accuracy of the information presented here. The text is presented in the language in which it was provided to SCC.