Fans and ventilators

Designation Number:
CAN/CSA-C22.2 NO. 113-18
Standard Type:
National Standard of Canada - Domestic
Standard Development Activity:
Reaffirmation
ICS code(s):
23.120
Status:
Proceeding to development
SDO Comment Period Start Date:
SDO Comment Period End Date:
Posted On:

Scope:

Scope

1.1
This Standard applies to fans and ventilation equipment that are

a) cord-connected, rated at not more than 250 V;
b) permanently connected to supply circuits of 600 V or less, single-phase or three-phase;
c) used in non-hazardous locations;
d) used in household or commercial locations;
e) used indoors or outdoors; and
f) used in accordance with the Rules of the Canadian Electrical Code, Part I.

1.2
This Standard applies to roof- and wall-mounted power ventilators; exhaust and filter units consisting of an air-circulating fan and a mechanical filter; fans for use in unattended areas; clothes dryer booster fans for use in the exhaust duct of household clothes dryers; blowers intended for household, commercial or industrial use, and air curtains without any heating.

1.3
This Standard applies to fans such as wall insert, ceiling insert, attic, bathtub and shower stall, and household downdraft fans. It also applies to fan-type air-to-air heat exchangers, component fans including extra-low-voltage component fans, and commercial fans and blowers used for carpet cleaning or flood restoration and remediation.

1.4
This Standard does not apply to products that are within the scope of CAN/CSA-C22.2 No. 60335-2-80, such as ceiling fans, desk or table fans, hassock fans, suitcase or box fans, pedestal fans, agricultural fans, partition fans, and duct fans.

1.5
This Standard does not apply to range hoods that are within the scope of standard CAN/CSA-C22.2 No. E60335-2-31.

1.6
This Standard also does not apply to the following products:

a) air-conditioning equipment;
b) electric air heaters;
c) fan coil units;
d) humidifiers;
e) evaporative coolers; f
) electrostatic or ionizer air cleaners;
g) air cleaners that intentionally produce ozone;
h) blowers of particulate matter;
i) air-to-air heat exchangers with gas- or oil-fired heating means;
j) air curtains with heaters;
k) fans and ventilators intended to exhaust flammable vapours;
l) fans and ventilators intended to be used with vehicle exhaust systems; and
m) combination microwave/range hood units.

1.7
Throughout this Standard, the term fan also includes ventilators.

1.8
The values given in SI units are the units of record for the purposes of this Standard. The values given in parentheses are for information and comparison only.

1.9
In this Standard, shall is used to express a requirement, i.e., a provision that the user is obliged to satisfy in order to comply with the Standard; should is used to express a recommendation or that which is advised but not required; and may is used to express an option or that which is permissible within the limits of the Standard.

Notes accompanying clauses do not include requirements or alternative requirements; the purpose of a note accompanying a clause is to separate from the text explanatory or informative material.

Notes to tables and figures are considered part of the table or figure and may be written as requirements.

Annexes are designated normative (mandatory) or informative (non-mandatory) to define their application.

Project need:

Project Need
To review the Standard within the required 5 year period.

Note: The information provided above was obtained by the Standards Council of Canada (SCC) and is provided as part of a centralized, transparent notification system for new standards development. The system allows SCC-accredited Standards Development Organizations (SDOs), and members of the public, to be informed of new work in Canadian standards development, and allows SCC-accredited SDOs to identify and resolve potential duplication of standards and effort.

Individual SDOs are responsible for the content and accuracy of the information presented here. The text is presented in the language in which it was provided to SCC.