Extra-low-voltage landscape lighting systems

Logo
CSA Group
Standards Development Organisation:
Working Program:
Designation Number:
CSA C22.2 NO. 250.7
Standard Type:
National Standard of Canada - Domestic
Standard Development Activity:
New Edition
ICS code(s):
29.260.10
91.160
Status:
Proceeding to development
SDO Comment Period Start Date:
SDO Comment Period End Date:
Posted On:

Scope:

Scope

1.1
This Standard applies to extra-low-voltage landscape lighting systems and associated components that are intended for cord-connected, direct plug-in, or permanent connection to a branch circuit of not more than 150 volts-to-ground in accordance with the Canadian Electrical Code, Part I.

1.2
This Standard only covers extra-low-voltage landscape lighting systems where the maximum output circuit is 300 VA or 25 A, whichever is less, from each of the secondary safety extra-low-voltage circuits (SELV).

1.3
Extra-low-voltage landscape lighting systems covered by this Standard are intended for gardens, walkways, patio areas, or similar outdoor locations, and for specific indoor locations such as atriums and shopping malls in accordance with the marking on the product.

1.4
This Standard applies to the following associated components:

a) the isolating-type power supply;
b) one or more luminaire assemblies of the incandescent, fluorescent, LED, or HID type; and
c) flexible cable and associated connectors intended for use in the secondary circuit.

1.5
This Standard does not apply to luminaires covered by the following standards:

a) submersible luminaires covered by CSA C22.2 No. 89;
b) Christmas tree and other decorative lighting outfits covered by CSA C22.2 No. 37; and
c) portable luminaires covered by CSA C22.2 No. 250.4.

1.6
In this Standard, shall is used to express a requirement, i.e., a provision that the user is obliged to satisfy in order to comply with the Standard; should is used to express a recommendation or that which is advised but not required; and may is used to express an option or that which is permissible within the limits of the Standard.

Notes accompanying clauses do not include requirements or alternative requirements; the purpose of a note accompanying a clause is to separate from the text explanatory or informative material.

Notes to tables and figures are considered part of the table or figure and may be written as requirements.

Annexes are designated normative (mandatory) or informative (non-mandatory) to define their application.

1.7
The values given in SI units are the units of record for the purposes of this Standard. The values given in parentheses are for information and comparison only.

Project need:

Project Need
This Standard contains specific requirements for extra-low-voltage landscape lighting systems and is intended to be used together with the requirements for luminaires contained in CSA C22.2 No. 250.0-04, Luminaires. This Standard applies to extra-low-voltage landscape lighting systems and associated components that are intended for cord-connected, direct plug-in, or permanent connection to a branch circuit of not more than 150 volts-to-ground in accordance with the Canadian Electrical Code, Part I.

Note: The information provided above was obtained by the Standards Council of Canada (SCC) and is provided as part of a centralized, transparent notification system for new standards development. The system allows SCC-accredited Standards Development Organizations (SDOs), and members of the public, to be informed of new work in Canadian standards development, and allows SCC-accredited SDOs to identify and resolve potential duplication of standards and effort.

Individual SDOs are responsible for the content and accuracy of the information presented here. The text is presented in the language in which it was provided to SCC.