Explosive atmospheres — Part 15: Equipment protection by type of protection "n”
Scope:
This part of IEC 60079 specifies requirements for the construction, testing and
marking for Group II electrical equipment with type of protection “n” which includes;
sealed devices “nC”, hermetically sealed devices “nC”, non-incendive components
“nC” and restricted breathing enclosures “nR” intended for use in explosive gas
atmospheres. This part of IEC 60079 applies to electrical equipment where the rated
input voltage does not exceed 15 kV r.m.s. AC or
DC including where the internal working voltages of the Ex product exceeds 15 kV, for
example starters for HID luminaires.
This part of IEC 60079 supplements and modifies the general requirements of IEC
60079-0, except as indicated in Table 1. Where a requirement of this part of IEC
60079 conflicts with a requirement of IEC 60079-0, the requirement of this part of IEC
60079 takes precedence.
Project need:
Note: The information provided above was obtained by the Standards Council of Canada (SCC) and is provided as part of a centralized, transparent notification system for new standards development. The system allows SCC-accredited Standards Development Organizations (SDOs), and members of the public, to be informed of new work in Canadian standards development, and allows SCC-accredited SDOs to identify and resolve potential duplication of standards and effort.
Individual SDOs are responsible for the content and accuracy of the information presented here. The text is presented in the language in which it was provided to SCC.