Down tower power cables for wind turbine applications rated 2 - 35 kV

Logo
CSA Group
Standards Development Organisation:
Working Program:
Designation Number:
C22.2 NO. 96.2
Standard Type:
National Standard of Canada - Domestic
Standard Development Activity:
New Edition
Status:
Proceeding to development
SDO Comment Period Start Date:
SDO Comment Period End Date:
Posted On:

Scope:

Scope

1.1
This Standard specifies construction and testing requirements for single conductor rated 2 kV, single metallic shielded or three conductor metallic shielded power cables rated 5 kV to 35 kV, normally used in wind turbine down tower applications where the cables are subject to frequent flexing and where installation is in accordance with the Canadian Electrical Code, Part I.

1.2
The cable constructions specified in this Standard are suitable for use at a maximum conductor temperature of 90 °C under normal operating conditions in wet or dry locations, in the down towers of wind turbines.

1.3
This Standard specifies the following categories of thermoset insulated cables:

Clause 5 - Three-conductor metallic shielded, round flexible power cables for wind turbines, rated 5 kV to 35 kV.

Clause 6 - DLO-DT cable, single conductor, used for general permanent applications rated 2 kV.

Clause 7 - Single-conductor metallic shielded, round flexible power cables for wind turbines, rated 5 kV to 35 kV.

1.4
The values given in SI (metric) units are the standard. The values given in parentheses are for information only.

1.5
In this Standard, "shall" is used to express a requirement, i.e., a provision that the user is obliged to satisfy in order to comply with the standard; "should" is used to express a recommendation or that which is advised but not required; and "may" is used to express an option or that which is permissible within the limits of the Standard.

Notes accompanying clauses do not include requirements or alternative requirements; the purpose of a note accompanying a clause is to separate from the text explanatory or informative material.

Notes to tables and figures are considered part of the table or figure and may be written as requirements.

Annexes are designated normative (mandatory) or informative (non-mandatory) to define their application

Project need:

Project Need
na

Note: The information provided above was obtained by the Standards Council of Canada (SCC) and is provided as part of a centralized, transparent notification system for new standards development. The system allows SCC-accredited Standards Development Organizations (SDOs), and members of the public, to be informed of new work in Canadian standards development, and allows SCC-accredited SDOs to identify and resolve potential duplication of standards and effort.

Individual SDOs are responsible for the content and accuracy of the information presented here. The text is presented in the language in which it was provided to SCC.