Backflow preventers and vacuum breakers

Designation Number:
CSA B64 SERIES
Standard Type:
National Standard of Canada - Domestic
Standard Development Activity:
New Edition
ICS code(s):
23.060.99
Status:
Open for SDO comment
SDO Comment Period Start Date:
SDO Comment Period End Date:
Posted On:

Scope:

Scope

CSA B64.0 - Definitions, general requirements, and test methods for vacuum breakers and backflow preventers

 

Scope

 

1.1

The CSA B64 Series covers vacuum breakers and backflow preventers that are used in potable water supply systems to prevent cross-connections.

 

1.2

This Standard specifies definitions, general requirements, test methods, markings, and instructions that are common to some or all of the Standards in the CSA B64 Series.

 

1.3

This Standard is not a complete Standard in itself and is intended to be used in conjunction with one of the Standards in the CSA B64 Series to form a complete Standard for a particular type of vacuum breaker or backflow preventer.

 

1.4

In this Standard, "shall" is used to express a requirement, i.e., a provision that the user is obliged to satisfy in order to comply with each Standard in the Series; "should" is used to express a recommendation or that which is advised but not required; and "may" is used to express an option or that which is permissible within the limits of the Standards in the Series.

 

Notes accompanying clauses do not include requirements or alternative requirements; the purpose of a note accompanying a clause is to separate from the text explanatory or informative material.

 

Notes to tables and figures are considered part of the table or figure and may be written as requirements.

 

Annexes are designated normative (mandatory) or informative (non-mandatory) to define their application.

 

1.5

This Standard is written in SI units, which are the units of record for the purposes of this Standard.

 

For conversion tables, see Annex A. Vacuum is expressed in pressure below ambient. All pipe sizes are shown as nominal pipe sizes (NPS).

 

--------------------------------------------------------------------------------------------------------------------------------

 

CSA B64.1.1 - Atmospheric vacuum breakers (AVB)

 

Scope

 

1.1

This Standard covers atmospheric vacuum breakers (AVB).

 

--------------------------------------------------------------------------------------------------------------------------------

 

CSA B64.1.2 - Pressure vacuum breakers (PVB)

 

Scope

 

1.1

This Standard covers pressure vacuum breakers (PVB).

 

--------------------------------------------------------------------------------------------------------------------------------

 

CSA B64.1.3 - Spill-resistant pressure vacuum breakers (SRPVB)

 

Scope

 

1.1

This Standard covers spill-resistant pressure vacuum breakers (SRPVB).

 

--------------------------------------------------------------------------------------------------------------------------------

 

CSA B64.1.4 - Vacuum breaker, air space type (ASVB)

 

Scope

 

1.1

This Standard covers manufactured vacuum breakers, air space type (ASVB).

 

--------------------------------------------------------------------------------------------------------------------------------

 

CSA B64.2 - Hose connection vacuum breakers (HCVB)

 

Scope

 

1.1

This Standard covers hose connection vacuum breakers (HCVB).

 

--------------------------------------------------------------------------------------------------------------------------------

 

CSA B64.2.1 -Hose connection vacuum breakers (HCVB) with manual draining feature

 

Scope

 

1.1

This Standard covers hose connection vacuum breakers (HCVB) that incorporate a draining feature that requires manual operation.

 

--------------------------------------------------------------------------------------------------------------------------------

 

CSA B64.2.1.1 -Hose connection dual check vacuum breakers (HCDVB)

 

Scope

 

1.1

This Standard covers hose connection vacuum breakers that have two check valves (HCDVB) and that incorporate a draining feature that requires manual operation. The second (downstream) check valve is field-testable.

 

--------------------------------------------------------------------------------------------------------------------------------

 

CSA B64.2.2 - Hose connection vacuum breakers (HCVB) with automatic draining feature

 

Scope

 

1.1

This Standard covers hose connection vacuum breakers (HCVB) that incorporate an automatic draining feature that does not require manual operation.

 

--------------------------------------------------------------------------------------------------------------------------------

 

CSA B64.3 - Dual check valve backflow preventers with atmospheric port (DCAP)

 

Scope

 

1.1

This Standard covers dual check valve backflow preventers with an atmospheric port (DCAP).

 

--------------------------------------------------------------------------------------------------------------------------------

 

CSA B64.3.1 - Dual check valve backflow preventers with atmospheric port for carbonators (DCAPC)

 

Scope

 

1.1

This Standard covers dual check valve backflow preventers with an atmospheric port for carbonators (DCAPC).

 

-------------------------------------------------------------------------------------------------------------------------------

 

CSA B64.4 - Reduced pressure principle (RP) backflow preventers

 

Scope

 

1.1

This Standard covers reduced pressure principle (RP) backflow preventers.

 

--------------------------------------------------------------------------------------------------------------------------------

 

CSA B64.4.1 - Reduced pressure principle backflow preventers for fire protection systems (RPF)

 

Scope

 

1.1

This Standard covers reduced pressure principle backflow preventers specifically designed for use in fire protection systems (RPF).

 

--------------------------------------------------------------------------------------------------------------------------------

 

CSA B64.5 - Double check valve (DCVA) backflow preventers

 

Scope

 

1.1

This Standard covers double check valve (DCVA) backflow preventers.

 

--------------------------------------------------------------------------------------------------------------------------------

 

CSA B64.5.1 - Double check valve backflow preventers for fire protection systems (DCVAF)

 

Scope

 

1.1

This Standard covers double check valve backflow preventers specifically designed for use in fire protection systems (DCVAF).

 

--------------------------------------------------------------------------------------------------------------------------------

 

CSA B64.6 - Dual check valve (DuC) backflow preventers

 

Scope

 

1.1

This Standard covers dual check valve (DuC) backflow preventers.

 

--------------------------------------------------------------------------------------------------------------------------------

 

CSA B64.6.1 - Dual check valve backflow preventers for fire protection systems (DuCF)

 

Scope

 

1.1

This Standard covers dual check valve backflow preventers designed for use in fire protection systems (DuCF).

 

--------------------------------------------------------------------------------------------------------------------------------

 

CSA B64.7 - Laboratory faucet vacuum breakers (LFVB)

 

Scope

 

1.1

This Standard covers vacuum breakers for use on laboratory faucets.

 

--------------------------------------------------------------------------------------------------------------------------------

 

CSA B64.8 - Dual check valve backflow preventers with intermediate vent (DuCV)

 

Scope

 

1.1

This Standard covers dual check valve backflow preventers with an intermediate vent (DuCV).

 

Note: These devices are designed to be used on individual outlets or appliances with flow rates of 0.25 L/s or less.

 

-------------------------------------------------------------------------------------------------------------------------------

 

CSA B64.9 - Single check valve backflow preventers for fire protection systems (SCVAF)

 

Scope

 

1.1

This Standard covers single check valve backflow preventers specifically designed for use in fire protection systems (SCVAF).

Project need:

Project Need

To update the current standard due to user experience/feedback/new technology.This proposed New Edition is being developed at the request of the B64 Technical Committee. It will provide the industry with up to date specifications for vacuum breakers and backflow preventers used in potable water supply systems. This will meet the strategic needs of the following key interests: a) ensuring that the latest innovative/technology/safety features are available for users, b) addressing needs of regulators by providing suitable requirements; and c) supporting certification bodies.

Note: The information provided above was obtained by the Standards Council of Canada (SCC) and is provided as part of a centralized, transparent notification system for new standards development. The system allows SCC-accredited Standards Development Organizations (SDOs), and members of the public, to be informed of new work in Canadian standards development, and allows SCC-accredited SDOs to identify and resolve potential duplication of standards and effort.