Accessible design for the built environment Committee

Designation Number:
B651-18
Standard Type:
National Standard of Canada - Domestic
Standard Development Activity:
New Edition
ICS code(s):
91.140.01
Status:
Proceeding to development
SDO Comment Period Start Date:
SDO Comment Period End Date:
Posted On:

Scope:

Scope

1.1 Purpose
This Standard specifies technical requirements on how to make buildings and the exterior built environment accessible and safely usable by persons with physical, sensory, or cognitive
disabilities.
1.2 Application
This Standard describes technical requirements that can be used in the design and construction of new facilities or exterior environments, or in modifications to existing facilities. This Standard does not address the application of the technical requirements. The extent to which these requirements have to be applied is the responsibility of other authorities having jurisdiction.
1.3 Dimensions
This Standard contains minimum requirements based on adult dimensions. Dimensions are given in SI (metric) units (typically in millimetres) and, where converted from foot/pound (imperial) units, have been rounded off with respect to critical dimensions. All dimensions in figures are given in millimetres and are measured to the centreline, unless otherwise specified.
1.4 Commentary and figures
Commentary and figures are included for explanatory or illustrative purposes only and are not a mandatory part of the Standard. Figures are not to scale. If there is any difference between the text and figure (where provided), the text shall take precedence.

1.5 Annexes
Annexes A to C provide additional information on topics considered in the Standard. Annex D provides guidance for the design of outdoor trails and beach access routes. Annex E contains references for accessible outdoor recreational environments, to supplement the information and guidance provided in Annex D.
1.6 Terminology
In this Standard, “shall” is used to express a requirement, i.e., a provision that the user is obliged to satisfy in order to comply with the standard; “should” is used to express a recommendation or that which is advised but not required; and “may” is used to express an option or that which is permissible within the limits of the standard.
Commentary accompanying clauses do not include requirements or alternative requirements; the purpose of a
commentary accompanying a clause is to separate from the text explanatory or informative material.
Text accompanying tables and figures are considered part of the table or figure and may be written as requirements.
Annexes are designated normative (mandatory) or informative (non-mandatory) to define their application.
1.7 Large print
Consistent with the recommendations of the CSA B651 series of standards, and for ease of reading the information and universal accessibility, this Standard has been printed in a 14 point font size.

Project need:

Project Need
To update the Standard to reflect new technologies/stakeholder input.

Note: The information provided above was obtained by the Standards Council of Canada (SCC) and is provided as part of a centralized, transparent notification system for new standards development. The system allows SCC-accredited Standards Development Organizations (SDOs), and members of the public, to be informed of new work in Canadian standards development, and allows SCC-accredited SDOs to identify and resolve potential duplication of standards and effort.

Individual SDOs are responsible for the content and accuracy of the information presented here. The text is presented in the language in which it was provided to SCC.