Methods of testing petroleum and associated products — Test for ethyl mercaptan odorant in propane, field method
Scope:
This method is intended for the semi‑quantitative determination of ethyl mercaptan odorant (within the range of 5 to 48 mg/L) in liquid propane in order to confirm that recently stenched propane is odorized to the required level.
Two procedures are given which are intended for field application and may be suitable for use by non‑laboratory personnel after suitable training. A gas chromatographic method should be used for more precise, quantitative determination of ethyl mercaptan in propane.
Other low molecular weight mercaptans, such as methyl mercaptan, can interfere by giving a positive result.
The primary stain tube described in this method is suitable for Grade 1 propane but is not suitable for Grade 2 (commercial) propane, which normally contains more than 5% propylene by volume.
Project need:
Note: The information provided above was obtained by the Standards Council of Canada (SCC) and is provided as part of a centralized, transparent notification system for new standards development. The system allows SCC-accredited Standards Development Organizations (SDOs), and members of the public, to be informed of new work in Canadian standards development, and allows SCC-accredited SDOs to identify and resolve potential duplication of standards and effort.
Individual SDOs are responsible for the content and accuracy of the information presented here. The text is presented in the language in which it was provided to SCC.