Milk-based infant formula powders — Quantification of whey protein content by sodium dodecyl sulfate...
This document specifies a method for the determination of the whey to casein protein ratio, ranging from 20:80 to 80:20 in cow milk-based infant formula powders. This method does not apply to the analysis of infant formulas containing hydrolysed protein or proteins from other sources (e.g. plants or milk from other mammals).
Publisher :
ISO
Status :
Published
Published Date :
2020-02-11
ICS Code(s) :
67.100.01
Solid biofuels — Simplified sampling method for small scale applications
This document describes simplified methods for taking samples of solid biofuels in small scale applications and storages including preparation of sampling plans and reports. The main focus is on storages with a size of ≤100 t. This document is applicable to the following solid biofuels: 1) fine (up to about 10 mm nominal top size) and regularly-shaped particulate materials that can be sampled…
Publisher :
ISO
Status :
Published
Published Date :
2020-02-10
ICS Code(s) :
27.190; 75.160.40
Assessment of power quality - Characteristics of electricity supplied by public networks
IEC TS 62749:2020 RLV contains both the official IEC International Standard and its Redline version. The Redline version is available in English only and provides you with a quick and easy way to compare all the changes between the official IEC Standard and its previous edition. IEC TS 62749:2020 specifies the expected characteristics of electricity at the SUPPLY TERMINALS of public low,…
Publisher :
IEC
Status :
Published
Published Date :
2020-02-10
ICS Code(s) :
17.220.99
Assessment of power quality - Characteristics of electricity supplied by public networks
IEC TS 62749:2020 specifies the expected characteristics of electricity at the SUPPLY TERMINALS of public low, medium and high voltage, 50 Hz or 60 Hz, networks. NOTE 1 The boundaries between the various voltage levels can be different for different countries/regions. In the context of this TS, the following terms for system voltage are used: - low voltage (LV) refers to less than or equal to 1…
Publisher :
IEC
Status :
Published
Published Date :
2020-02-10
ICS Code(s) :
17.220.99
Nanomanufacturing - Key control characteristics - Part 4-8: Nano-enabled electrical energy storage -...
IEC TS 62607-4-8:2020 specifies a test method for the determination of water content in electrode nanomaterials for nano-enabled electrical energy storage devices, using the Karl Fischer coulometric titration method. This document includes: - recommendations for sample preparation, - outlines of the experimental procedures used to measure electrode nanomaterial properties, and - methods of…
Publisher :
IEC
Status :
Published
Published Date :
2020-02-06
ICS Code(s) :
07.030; 07.120
Steel — Determination of vanadium content — Flame atomic absorption spectrometric method (FAAS)
This document specifies a flame atomic absorption spectrometric method (FAAS) for the determination of the vanadium content in steel. The method is applicable to vanadium contents between 0,01 % (mass fraction) and 0,80 % (mass fraction), provided that the tungsten content in a 1,0 g test portion is not higher than 1,0 % and/or the titanium content is not higher than 0,5 %.
Publisher :
ISO
Status :
Published
Published Date :
2020-02-06
ICS Code(s) :
77.080.01
Steel and cast iron — Determination of silicon content — Gravimetric method
This document specifies a gravimetric method for the determination of the silicon content in steel and cast iron. The method is applicable to silicon contents between 0,10 % (mass fraction) and 5,0 % {mass fraction). NOTE For samples containing molybdenum, niobium, tantalum, titanium, tungsten, zirconium or high levels of chromium, the results are less accurate than for unalloyed matrixes.
Publisher :
ISO
Status :
Published
Published Date :
2020-02-05
ICS Code(s) :
77.080.01
Road vehicles — Clock extension peripheral interface (CXPI) — Part 4: Data link layer and physical l...
This document specifies the CXPI data link layer and the CXPI physical layer. The DLL is based on: — priority-based CXPI network access; — non-destructive content-based arbitration; — broadcast frame transfer and acceptance filtering; and — node related error detection and error signalling. The CXPI physical layer (PHY) requirements comprise of: — physical signalling (PS) sub-…
Publisher :
ISO
Status :
Published
Published Date :
2020-02-04
ICS Code(s) :
43.040.15
Jewellery and precious metals — Determination of high purity gold, platinum and palladium — Differen...
This document specifies the analytical procedure for the determination of gold, platinum and palladium with a nominal content of and above 999 ? (parts per thousand). This document specifies a method intended to be used as the recommended method for the determination of gold, platinum and palladium of fineness of and above 999 ?. For the determination of fineness of and above 999,9 ?,…
Publisher :
ISO
Status :
Published
Published Date :
2020-02-04
ICS Code(s) :
39.060
Jewellery and precious metals — Determination of high purity silver — Difference method using ICP-OE...
This document specifies the analytical procedure for the determination of silver with a nominal content of and above 999 ? (parts per thousand). This document specifies a method intended to be used as the recommended method for the determination of silver of fineness of and above 999 ?. For the determination of fineness of and above 999,9 ?, modifications described in Annex B apply.
Publisher :
ISO
Status :
Published
Published Date :
2020-02-04
ICS Code(s) :
39.060