Standard for the Servicing of Commercial Cooking Area Extinguishing Systems
1.1 These requirements apply to companies involved in installing and servicing of commercial cooking
area extinguishing systems and equipment in accordance with the National Fire Code of Canada (NFCC),
NFPA 17A, and the manufacturer’s installation, operation and maintenance manual.
NOTE: NFCC includes any Federal, Provincial, Territorial, or local legislation or regulations as may exist.
1.2…
NORME D'ENTRETIEN DES SYSTÈMES D'EXTINCTION DES AIRES DE CUISSON COMMERCIALES
1.1 Ces exigences s’appliquent aux sociétés en charge de l’installation et de l’entretien des systèmes et
matériels d’extinction dans les zones incluant un équipement de cuisson commercial, conformément au
Code national de prévention des incendies du Canada (CNPIC), à la norme NFPA 17A et aux manuels
d’installation, d’utilisation et de maintenance du fabricant.
REMARQUE : le CNPIC regroupe l’…
Packaging of Category A and Category B infectious substances (Class 6, Division 6.2) and clinical, (...
1.1 Organization and content
This National Standard of Canada sets out requirements for designing, manufacturing, marking, testing, selecting and using means of containment for the transportation of Category A and Category B infectious substances in Class 6, Division 6.2, solid medical waste of Category A and clinical, (bio) medical or regulated medical waste.
This standard consists of three…
Meters for Flammable and Combustible Liquids and LP-Gas
1 Scope
1.1 These requirements cover:
a) Meters for flammable and combustible liquids, of the type and size commonly used in the
assembly of motor fuel dispensing devices; and
b) Meters for liquefied petroleum gas (LP-Gas), of the type and size commonly used in the
assembly of motor fuel dispensing devices and tank trucks
The meters are of the positive liquid displacement type.
NOTE: For…
Compteurs de liquides inflammables et combustibles et de gaz de pétrole liquéfié
1 Domaine d’application
1.1 Ces exigences couvrent :
a) les compteurs pour liquides inflammables et combustibles, du type et de la taille couramment
utilisés dans l’assemblage des dispositifs de distribution de carburant pour moteurs; et
b) les compteurs de gaz de pétrole liquéfié (GPL), du type et de la taille couramment utilisés dans
l’assemblage des appareils de distribution de carburant…
Household and similar electrical appliances — Safety — Part 2-89: Particular requirements for commer...
1 Scope
This clause of Part 1 is replaced by the following.
This part of IEC 60335 specifies safety requirements for electrically operated commercial refrigerating
appliances and ICE-MAKERS that have an incorporated motor-compressor or that are supplied in two units
for assembly as a single appliance in accordance with the instructions (split system).
NOTE 101 Examples of appliances that are…
This National Standard of Canada applies to four grades of gasoline to which no lead or phosphorus compounds
have been added. They are intended for use in spark-ignition engines under a wide range of climatic conditions.
This standard is not intended to apply to the mixing of oxygenated gasolines and gasolines, either at the point of
retail sale or after the point of retail sale.
Gasoline…
Oxygenated automotive gasoline containing ethanol (E1-E10 and E11-E15)
This National Standard of Canada applies to two types of oxygenated gasoline, E1-E10 (“Type A”) and E11-E15
(“Type B”), to which no lead or phosphorus compounds have been added, and in which the oxygenate consists
essentially of ethanol. They are intended for use in spark-ignition engines under a wide range of climatic conditions.
Each type may be supplied in one of four grades which differ in…
Special requirements for plumbing installations in health care facilities
1 Scope
1.1 General
This Standard addresses the special requirements of plumbing systems pertinent to the design, construction, operation, and maintenance of health care facilities (HCFs). This Standard specifies requirements for the following in HCFs:
a)
water supply systems, including cold water systems and hot water systems;
b)
plumbing fixtures and fittings;
c)
drainage systems;
d)…
Cable management systems — Cable ties for electrical installations
1 Scope
This document specifies requirements for metallic, non-metallic and composite cable ties and their
associated fixing devices used for the management and support of wiring systems in electrical
installations.
1DV.1 D2 Modify Clause 1 by replacing the first paragraph with the following:
This Standard specifies requirements for metallic, non-metallic, and composite cable ties
and their…