Refine Results
Displaying 7621 - 7632 of 12005
Notice of Intent
Standard for Gas and Vapour Detectors and Sensors...
1.1 This Standard covers requirements for permanently installed, portable and transportable toxic and combustible gas and vapour detectors and sensors, including accessories, intended to be employed in indoor locations or...
Notice of Intent
STANDARD METHOD OF FIRE TESTS OF FIRESTOP SYSTEMS
1.1 This method of test is applicable to firestop systems with or without penetrating items such as cables, cable trays, conduits, ducts and pipes. These firestop systems are intended for use in openings in fire resistive...
Notice of Intent
Plant Oil Extraction Equipment for Installation...
1.1 This Standard covers commercial and industrial plant oil extraction equipment for installation and use indoors in ordinary (unclassified) locations and hazardous (classified) locations. Hazardous locations are also...
Notice of Intent
Standard for Gas and Vapour Detectors and Sensors...
This Standard covers requirements for permanently installed, portable and transportable toxic and combustible gas and vapour detectors and sensors, including accessories, intended to be employed in indoor locations or outdoor...
Notice of Intent
Standard Test Method for Determination of Long...
This procedure defines the long-term thermal resistance (LTTR) of a foam product as the value measured after 5-year storage in a laboratory environment and provides means for its prediction based on an accelerated laboratory...
Notice of Intent
STANDARD FOR FIRE TESTED ABOVEGROUND TANK ASSEMBLIES...
1 SCOPE 1.1 (REV1) This Standard covers minimum requirements for shop fabricated, aboveground fire tested tank assemblies intended for storage of flammable and combustible liquids that have a specific gravity not greater than...
Notice of Intent
Hose Nozzle Valves for Diesel Fuel, Biodiesel...
1.1 These requirements cover hose nozzle valves that are intended to be used for the control of motor fuels as indicated in 1.2. They are of the type used in motor fuel dispensing equipment. Hose nozzle valves covered by this...
Notice of Intent
Standard for Meters for Gasoline and Gasoline...
1.1 These requirements cover positive displacement liquid meters for use with motor fuels. Motor fuels, as defined by these requirements, include one or more of the fuels described in 1.2. 1.2 Meters for gasoline/ethanol...
Notice of Intent
Hose Nozzle Valves for Gasoline and Gasoline/...
1.1 These requirements cover hose nozzle valves that are intended to be used for the control of motor fuels as indicated in 1.3. They are of the type used in motor fuel dispensing equipment. Hose nozzle valves covered by this...
Notice of Intent
Standard for Strainers for Diesel Fuel, Biodiesel...
1.1 These requirements cover complete, self-contained strainer or filter assemblies intended for use with the fuels designated in 1.3. Although these devices are designated strainers, they may be either strainers or filters...
Notice of Intent
Standard for Emergency Breakaway Fittings, Swivel...
1.1 These requirements cover emergency breakaway fittings, swivel connectors and pipe-connecting fittings of the threadless compression type. Connectors and fittings covered by these requirements are intended only for the...
Notice of Intent
Standard for Emergency Breakaway Fittings, Swivel...
1.1 These requirements cover emergency breakaway fittings, swivel connectors and pipe-connecting fittings of the threadless compression type. Connectors and fittings covered by these requirements are intended only for the...