Notice of Intent
Prefabricated Gravity Grease Interceptors
This Standard covers prefabricated gravity grease interceptors made of concrete, fiber‐reinforced polyester (FRP), thermoplastic, or steel and specifies requirements for design, materials, performance, testing, and markings.
Notice of Intent
Standard for Categories 1 and 2 Foam Liquid Concentrates
1. The Standards for foam liquid concentrates are divided into three categories. Category 1 Primarily for use on general-purpose hydrocarbon fires Category 2 Primarily for use on polar solvents, oxygenated fuels, and water...
Notice of Intent
Exterior Insulation and Finish Systems (EIFS) - ...
This Standard outlines requirements for Exterior Insulation and Finish Systems (EIFS) installed in accordance with CAN/ULC-S716.2 and designed in accordance with CAN/ULC-S716.3, and used in combination with a drained air...
Notice of Intent
Exterior Insulation and Finish Systems (EIFS) – ...
This Standard contains requirements for the installation of Exterior Insulation and Finish Systems (EIFS) that meet the material and system requirements of CAN/ULC-S716.1 and the design requirements of CAN/ULC-S716.3. This...
Notice of Intent
Vault Ventilators and Vault Ventilatating Ports
1.1 These requirements cover emergency vault ventilators and vault-ventilating ports. 1.2 Emergency vault ventilators are primarily intended to provide fresh air to persons locked in the vault by accident or during a robbery...
Notice of Intent
Standard Methods of Fire Tests of Roof Coverings
1.1 The test methods described in this Standard are applicable to roof covering materials and are intended to measure the relative fire-performance characteristics of roof coverings when exposed to fire originating from...
Notice of Intent
Standard for Method of Fire Test of Fire Damper...
1.1 These requirements and methods of test apply to fire damper assemblies rated ¾ h, 1 h, 1½ h, 2 h, or 3 h for use in air-conditioning and ventilating system ducts or openings (without ducts) piercing horizontally or...
Notice of Intent
Standard Test Method for the Determination of...
1.1 This test method determines combustibility parameters for the assessment of degree of combustibility of building materials by measuring the heat release and smoke production from specimens exposed to radiant heat using...
Notice of Intent
Standard Method of Test for Fire Growth of Insulated...
1.1 This is a fire test response Standard. This document describes the test method used to determine the contribution to fire growth provided by a non-loadbearing insulated building panel installed in a sprinklered or...
Notice of Intent
Standard for Control Unit for Fire Alarm Systems
This Standard covers requirements for control units, fire alarm systems and control unit accessories for use in accordance with the Standard for the Installation of Fire Alarm Systems, CAN/ULC-S524, in accordance with Rule 32...