Notice of Intent
Motor-operated appliances (household and commercial...
1.1 This Standard applies to motor-operated appliances intended for use with nominal system voltages of 600 V and less, except that where appliances are driven by universal-type motors or electromagnetic mechanisms, the scope...
Household and similar electrical appliances - Safety - Part 2-89: Particular requirements for commercial refrigerating appliances with an incorporated or remote refrigerant unit or compressor
Scope: This clause of Part 1 is replaced by the following. This International Standard specifies safety requirements for electrically operated commercial refrigerating appliances that have an incorporated compressor or that...
Photovoltaic (PV) module safety qualification - Part 1: Requirements for construction
1 Scope and object [Add the following] The requirements of CAN/CSA-C22.2 No. 61730-1 and CAN/CSA-C22.2 No. 61730-2 address flat-plate PV modules that are used in systems where the maximum system voltage is equal to or less...
Notice of Intent
Technical requirements for in-service evaluation...
This Standard specifies the technical requirements for the licensee to ensure structural integrity of cold-worked Zr-2.5 wt% Nb alloy pressure tubes in operating CANDU reactors. Clause 13 of CSA N285.0/N285.6 Series requires...
Notice of Intent
Heating Fuel Oil
1.1 This standard applies to three types of middle distillate fuel oils that are suitable for use in liquid-fuel-burning equipment without preheating (Types 0, 1 and 2), and three types of fuel oils that contain residual fuel...
Automotive Diesel Fuel Containing Low Levels of Biodiesel (B1–B5)
1.1 This standard applies to two types of automotive diesel fuel containing low levels of biodiesel: Type A-ULS, Bx and Type B-ULS, Bx. 1.1.1 Bx represents biodiesel fuel containing x percent by volume of biodiesel component...
Diesel Fuel Containing Biodiesel (B6–B20)
1.1 This standard applies to one class of Type B ultra low sulphur diesel fuel (<15 ppm S) containing from 6% to 20% by volume of biodiesel. 1.1.1 Users of fuel meeting this standard are advised to refer to the owner’s manual...
Notice of Intent
Safety Requirements for Electrical Equipment ...
Scope and object This clause of part 1 is applicable, except as follows: Scope Replacement: This International Standard applies to the HAND-HELD and hand-manipulated CURRENT SENSORS described below. These CURRENT SENSORS are...
Notice of Intent
Anti-siphon fill valves for water closet tanks
1.1 This Standard covers anti-siphon fill valves intended to be installed in water closet tanks. Note: In this Standard, anti-siphon fill valves are also referred to as "devices". 1.2 In this Standard, "shall" is used to...
Notice of Intent
Standard for the Installation, Inspection and...
This Standard prescribes requirements for: A The installation of intrusion alarm systems. B The classification of extent of protection; and C The testing and inspection of intrusion alarm systems. Intrusion alarm systems are...
Notice of Intent
Testing of three-phase synchronous machines during...
1.1 This Standard covers three-phase, alternating current, salient pole synchronous machines 150 kW and up, 200 through 13,800 volts, 60 and 50 Hertz and will assist in verifying the machine efficiency has been maintained...
Notice of Intent
Lithium-Ion Battery Incident Response and Management...
The standard addresses incident response and management related to lithium-ion batteries and is designed to enhance knowledge of this subject so that related operations can be carried out effectively. Topics addressed include...