Search

Refine Results
International Classification for Standards (ICS) code
Source
Standards Development Organization (SDO) code
Language
Status
National Standards of Canada (NSC) code
Period range

From

To

Displaying 3171 - 3180 of 4321
Implants for surgery - Metallic materials - Part 2: Unalloyed titanium
This National Standard of Canada is equivalent to International Standard ISo 5832-2:1999. 1 Scope This part of ISO 5832 specifies the characteristics of, and corresponding test methods for, unalloyed titanium for use in the manufacture of surgical implants. Provisions is made for six grades of titanium based on tensile strength (see Table 2). NOTE The mechanical properties of a…
Publisher :
CSA
Status :
Withdrawn
Published Date :
2000-02-28
ICS Code(s) :
77.120.50; 11.040.40
Implants for surgery - Metallic materials - Part 3: Wrought titanium 6-aluminium 4-vanadium alloy
This National Standard of Canada is equivalent to International Standard ISO 5832-3:1996. 1 Scope This part of ISO 5832 specifies the characteristics of, and corresponding test methods for, the wrought titanium alloy known as titanium 6-aluminium 4-vanadium alloy (Ti 6-Al 4-V alloy) for use in the manufacture of surgical implants. NOTE 1 The mechanical properties of a sample obtained…
Publisher :
CSA
Status :
Withdrawn
Published Date :
2000-02-28
ICS Code(s) :
77.120.99; 11.040.40
Implants for surgery - Metallic materials - Part 4: Cobalt-chromium-molybdenum casting alloy
This National Standard of Canada is equivalent to International Standard ISO 5832-4:1996. 1 Scope This part of ISO 5832 specifies the characteristics of, and corresponding test methods for, cobalt-chromium-molybdenum casting alloy for use in the manufacture of surgical implants. NOTE 1 The mechanical properties of a sample obtained from a finished product made of this alloy may not…
Publisher :
CSA
Status :
Withdrawn
Published Date :
2000-02-28
ICS Code(s) :
77.120.99; 11.040.40
Implants for surgery - Metallic materials - Part 5: Wrought cobalt-chromium-tungsten-nickel alloy
This National Standard of Canada is equivalent to International Standard ISO 5832-5:1993. 1 Scope This part of ISO 5832 specifies the characteristics of, and corresponding test methods for, wrought cobalt-chromium-tungsten-nickel alloy for use in the manufacture of surgical implants. NOTE 1 The mechanical properties of a sample obtained from a finished product made of this alloy may…
Publisher :
CSA
Status :
Withdrawn
Published Date :
2000-02-28
ICS Code(s) :
77.120.99; 11.040.40
Implants for surgery - Metallic materials - Part 6: Wrought cobalt-nickel-chromium-molybdenum alloy
This National Standard of Canada is equivalent to International Standard ISO 5832-6:1997. 1 Scope This part of ISO 5832 specifies the characteristics of, and corresponding test methods for, wrought cobalt-nickel-chromium-molybdenum alloy for use in the manufacture of surgical implants. NOTE - The mechanical properties of a sample obtained from a finished product made of this alloy…
Publisher :
CSA
Status :
Withdrawn
Published Date :
2000-02-28
ICS Code(s) :
77.120.99; 11.040.40
Implants for surgery - Acrylic resin cements
This National Standard of Canada is equivalent to International Standard ISO 5833:1992. 1 Scope This International Standard applies to radio-opaque and non-radio-opaque cements and specifies physical, mechanical, packaging and labelling requirements for self-curing resin cement based on poly(methacrylic acid esters), of two types intended respectively for use with a syringe or in the…
Publisher :
CSA
Status :
Withdrawn
Published Date :
2000-02-28
ICS Code(s) :
11.040.40
Implants for surgery - Metal bone screws with hexagonal drive connection, spherical under-surface of...
This National Standard of Canada is equivalent to International Standard ISO 5835:1991. 1 Scope This International Standard specifies dimensions and tolerances for metal bone screws used in surgery, having hexagonal drive connection, spherical under-surface of the head, and shallow and deep asymmetrical threads. NOTEs 1 The mechanical requirements for screws that are cited in…
Publisher :
CSA
Status :
Withdrawn
Published Date :
2000-02-28
ICS Code(s) :
11.040.40
Implants for surgery - Partial and total hip joint prostheses - Part 2: Articulating surfaces made o...
This National Standard of Canada is equivalent to International Standard ISO 7206-2:1996. 1 Scope This part of ISO 7206 specifies requirements for the articulating surfaces of those types of total and partial hip joint prostheses that provide a joint replacement of ball and socket configuration, as follows: a) sphericity and surface finish requirements for metallic and ceramic…
Publisher :
CSA
Status :
Withdrawn
Published Date :
2000-02-28
ICS Code(s) :
11.040.40
Implants for surgery - Femoral and tibial components for partial and total knee joint prostheses - P...
This National Standard of Canada is equivalent to International Standard ISO 7207-1:1994. 1 Scope This part of ISO 7207 classifies femoral and tibial components for knee joint prostheses in which one or both bearing surfaces of at least one compartment of the knee are replaced, and gives definitions of components and the designation of dimensions. Patellar components and prostheses…
Publisher :
CSA
Status :
Withdrawn
Published Date :
2000-02-28
ICS Code(s) :
11.040.40
Orthopaedic instruments - Drive connections - Part 1: Keys for use with screws with hexagon socket h...
This National Standard of Canada is equivalent to International Standard ISO 8319-1:1996. 1 Scope This part of ISO 8319 specifies the dimensions, tolerances, mechanical properties and performance requirements of the working end of keys to be used for inserting and removing metal bone screws with hexagon drive sockets, used as surgical implants. Screw keys with a working end specified…
Publisher :
CSA
Status :
Withdrawn
Published Date :
2000-02-28
ICS Code(s) :
11.040.30