Search

Refine Results
International Classification for Standards (ICS) code
Source
Standards Development Organization (SDO) code
Language
Status
National Standards of Canada (NSC) code
Period range

From

To

Displaying 591 - 600 of 1867
Spécification relative aux essais des câblages symétriques et coaxiaux des technologies de l’informa...
l’IEC 61935-1-2:2018 spécifie les procédures de mesure de référence supplémentaires pour le mesurage de l’asymétrie de résistance avec des instruments d’essai sur site et les exigences relatives à l’exactitude des contrôleurs sur site pour mesurer l’asymétrie de résistance conformément aux exigences de l'ISO/IEC 11801-1.
Publisher :
IEC
Status :
Published
Published Date :
2018-12-13
ICS Code(s) :
33.120.10
Low-voltage switchgear and controlgear assemblies - Part 7: Assemblies for specific applications suc...
IEC 61439-7:2018 defines the specific requirements of assemblies as follows: - assemblies for which the rated voltage does not exceed 1 000 V in the case of AC or 1 500 V in the case of DC; – assemblies intended for use in connection with the generation, transmission, distribution and conversion of electric energy, and for the control of electric energy consuming equipment; – assemblies…
Publisher :
IEC
Status :
Revised
Published Date :
2018-12-05
ICS Code(s) :
29.130.20
UHV AC transmission systems - Part 301: On-site acceptance tests
IEC TS 63042-301:2018(E) applies to on-site acceptance tests of electrical equipment with the highest voltages of AC transmission system exceeding 800 kV.
Publisher :
IEC
Status :
Published
Published Date :
2018-12-05
ICS Code(s) :
29.240.01
Power installations exceeding 1 kV a.c. — Part 1: Common rules Installations électriques en courant...
1 Scope This Standard applies to indoor substations, generating stations, and fenced outdoor supply stations and substations (including supply substations on customer premises). For the purpose of interpreting this Standard, an electrical power installation is considered to be one of the following: a) a substation, i.e., a closed electrical operating area in a transmission or distribution…
Publisher :
CSA
Status :
Standard
Published Date :
2018-11-30
ICS Code(s) :
29.020; 29.080.01
Photometric performance of roadway and street lighting luminaires
1 Scope 1.1 This Standard specifies photometric performance requirements for luminaires that are used for roadway and street lighting applications as a function of unit power density (UPD). 1.2 The following light sources are addressed in this Standard: a) clear HPS lamp b) clear metal halide lamp and c) LED. 1.3 This Standard is based on a) average luminance, luminance uniformity…
Publisher :
CSA
Status :
Standard
Published Date :
2018-11-30
ICS Code(s) :
29.140.40; 93.080.40
STANDARD FOR THERMAL INSULATION – SPRAY APPLIED RIGID POLYURETHANE FOAM, MEDIUM DENSITY – MATERIAL S...
1.1 This Standard provides the physical property requirements and test methods to determine the material properties for medium density closed cell spray-applied rigid polyurethane foam, used for thermal insulation or for other purposes in building and non-building applications in both site-built construction and prefabrication (manufacturing) facilities. 1.2 The spray polyurethane foam system…
Publisher :
ULC
Status :
Standard
Published Date :
2018-11-30
ICS Code(s) :
91.120.10
Soil quality — Characterization of contaminated soil related to groundwater protection
This document provides guidance on the principles behind, and main methods for, the evaluation of sites, soils and soil materials in relation to their role as a source of contamination of groundwater and their function in retaining, releasing and transforming contaminants. It is focused on contaminated land management identifying and listing relevant monitoring strategies, methods for sampling,…
Publisher :
ISO
Status :
Published
Published Date :
2018-11-25
ICS Code(s) :
13.080.40
Qualité du sol — Caractérisation des sols pollués en relation avec la protection des eaux souterrain...
Le présent document fournit des recommandations relatives aux principes sous-jacents et aux principales méthodes régissant l'évaluation des sites, des sols et des matériaux du sol, à leur rôle en tant que source de pollution des eaux souterraines et à leur fonction de rétention, d'émission et de transformation des polluants. Il est axé sur la gestion des sites et sols pollués ainsi que…
Publisher :
ISO
Status :
Published
Published Date :
2018-11-25
ICS Code(s) :
13.080.40
Fibres optiques - Partie 1-32: Méthodes de mesure et procédures d'essai - Dénudabilité du revêt...
L'IEC 60793-1-32:2018 est destinée principalement aux essais des fibres, dès leur production par un fabricant de fibres, ou après revêtement ultérieur (revêtement protecteur serré) au moyen de divers polymères. L'essai peut être effectué sur des fibres issues de production, ou bien après exposition à divers environnements. Le présent essai s'applique aux fibres de types A1, A2, A3…
Publisher :
IEC
Status :
Published
Published Date :
2018-11-15
ICS Code(s) :
33.180.10
Air quality — Environmental meteorology — Part 3: Ground-based remote sensing of wind by continuous-...
This document specifies the requirements and performance test procedures for monostatic heterodyne continuous-wave (CW) Doppler lidar techniques and presents their advantages and limitations. The term "Doppler lidar" used in this document applies solely to monostatic heterodyne CW lidar systems retrieving wind measurements from the scattering of laser light by aerosols in the atmosphere…
Publisher :
ISO
Status :
Published
Published Date :
2018-11-13
ICS Code(s) :
07.060