Electromagnetic Compatibility (EMC) - Part 4: Testing and Measurement Techniques - Section 4: Electr...
This National Standard of Canada is equivalent to International Standard CEI/IEC 1000-4-4:1995, first edition, 1995-01, including Amendment 1:2000.
This International Standard relates to the immunity requirements and test methods for electrical and electronic equipment to repetitive electrical fast transients. It additionally defines ranges of test levels and establishes test procedures.…
Electromagnetic Compatibility (EMC) - Part 4-2: Testing and Measurement Techniques - Electrostatic D...
This National Standard of Canada is equivalent to International Standard CEI/IEC 61000-4-2:1995+A1:1998 (edition 1.1, 1999-05).
This International Standard relates to the immunity requirements and test methods for electrical and electronic equipment subjected to static electricity discharges, from operators directly, and to adjacent objects. It additionally defines ranges of test levels which…
Electromagnetic Compatibility (EMC) - Part 4: Testing and Measurement Techniques - Section 12: Oscil...
This National Standard of Canada is equivalent to International Standard CEI/IEC 1000-4-12: 1995 (first edition, 1995-05).
This section of IEC 1000-4 relates to the immunity requirements and test methods for electrical and electronic equipment, under operational conditions, to oscillatory waves represented by:
(a) non-repetitive damped oscillatory transients (ring wave) occurring in low-voltage…
Electromagnetic Compatibility (EMC) - Part 4: Testing and Measurement Techniques - Section 5: Surge ...
This National Standard of Canada is equivaent to International Standard CEI/IEC 1000-4-5: 1995 (first edition, 1995-02).
This section of IEC 1000-4 relates to the immunity requirements, test methods, and range of recommended test levels for equipment to unidirectional surges caused by overvoltages from switching and lightning transients. Several test levels are defined which relate to…
Handling of Waste Materials in Health Care Facilities and Veterinary Health Care Facilities
1. Scope
Note: In many guidelines, all waste contaminated with blood or body fluids is classified as biomedical waste. This enormously increases the volume of waste requiring expensive handling and disposal. Identical items of waste are disposed of from homes with no special handling or decontamination.
The identification of every client who carries a blood borne pathogen including, but…
Calibration of fibre optic chromatic dispersion test sets
Defines standard procedures for calibrating optical fibre chromatic dispersion test sets. The procedures apply to calibration laboratories, and to manufacturers and users of CD test sets, for: (a) calibrating CD test sets, (b) setting specifications of CD test sets, (c) extending the calibration period of an already calibrated CD test set.
It applies to all CD test sets, except for multimode…
Safety requirements for electrical equipment for measurement, control, and laboratory use - Part 1: ...
Specifies general safety requirements for electrical equipment intended for professional, industrial process, and educational use. It applies to 4 main groups of equipment: (a) Electrical test and measurement equipment such as signal generators, measurement standards, power supplies, transducers, transmitters, etc. (b) Electrical control equipment to control specific values by manual setting,…
Industrial automation systems and integration — Product data representation and exchange — Part 34: ...
This part of ISO 10303 specifies the abstract test methods for conformance testing of an implementation
of an ISO 10303 Application Protocol (AP). The scope is limited to the following implementation
methods:
— preprocessors that claim to generate 10303 schema instances represented as exchange structures as
defined by ISO 10303-21;
— postprocessors that claim to accept and process 10303 schema…
Reference neutron radiations — Part 1: Characteristics and methods of production
This part of ISO 8529 specifies the reference neutron radiations, in the energy range from thermal up to 20 MeV,
for calibrating neutron-measuring devices used for radiation protection purposes and for determining their response
as a function of neutron energy. Reference radiations are given for neutron fluence rates of up to 1 _ 109 m?2_s?1,
corresponding, at a neutron energy of 1 MeV, to dose-…
Standard for Cellulose Fibre Insulation (CFI) for Buildings
1. SCOPe
1.1
This Standard specifies requirements for treated wood-based cellulose
fibre intended for use as thermal insulation (cellulose fibre insulation, CFI)
in new and existing buildings within the temperature range of -60°C to 90°C.
1.2
This Standard describes general requirements for the material and
additional requirements specific to applications. The applications are…