Animal feeding stuffs — Determination of zearalenone by immunoaffinity column chromatography and hig...
ISO 17372:2007 is applicable to the analysis of zearalenone in animal feed and feed ingredients, including barley, corn, oats, rye, wheat, soybean meal, canola (rapeseed) meal, corn gluten, dried distillers' grains, lentils, and sugar beet pulp. The limit of quantification is 0,05 mg/kg (50 µg/kg). A lower limit of quantification may be achievable subject to appropriate validation being…
Publisher :
ISO
Status :
Published
Published Date :
2008-01-29
ICS Code(s) :
65.120
Electrical equipment for measurement, control and laboratory use - EMC requirements - Part 3-1: Immu...
IEC 61326-1 applies to this part of IEC 61326 but is limited to systems and equipment for industrial applications intended to perform safety functions as defined in IEC 61508 with SIL 1-3. The electromagnetic environments encompassed by this product family standard are industrial, both indoor and outdoor, as described for industrial locations in IEC 61000-6-2 or defined in 3.7 of IEC 61326-1.…
Publisher :
IEC
Status :
Revised
Published Date :
2008-01-29
ICS Code(s) :
25.040.40; 33.100.20
Electrical equipment for measurement, control and laboratory use - EMC requirements - Part 3-2: Immu...
IEC 61326-1 applies to this part of IEC 61326 but is limited to systems and equipment for industrial applications within a specified electromagnetic environment and intended to perform safety functions as defined in IEC 61508 with SIL 1-3. The electromagnetic environments encompassed by this product family standard are industrial, both indoor and outdoor, as they can be found in industrial…
Publisher :
IEC
Status :
Revised
Published Date :
2008-01-29
ICS Code(s) :
25.040.40; 33.100.20
Health informatics — Point-of-care medical device communication — Part 90101: Analytical instruments...
ISO 11073-90101:2008 establishes a set of specifications to allow seamless multivendor interoperability and communication between point-of-care devices, data concentrators, and clinical information systems. CLSI document POCT1 provides the framework for engineers to design devices, workstations and interfaces that allow multiple types and brands of point-of-care devices to communicate…
Publisher :
ISO
Status :
Published
Published Date :
2008-01-07
ICS Code(s) :
35.240.80
Electromagnetic Compatibility (EMC) - Part 4-5: Testing and Measurement Techniques - Surge Immunity ...
This National Standard of Canada is equivalent to International Standard IEC 61000-4-5:2005. 1 Scope and object This part of IEC 61000 relates to the immunity requirements, test methods, and range of recommended test levels for equipment to unidirectional surges caused by overvoltages from switching and lightning transients. Several test levels are defined which relate to different environment…
Publisher :
CSA
Status :
Standard
Published Date :
2007-12-31
ICS Code(s) :
33.100.20
Petroleum and natural gas industries — Equations and calculations for the properties of casing, tubi...
ISO/TR 10400:2007 illustrates the equations and templates necessary to calculate the various pipe properties given in International Standards, including pipe performance properties, such as axial strength, internal pressure resistance and collapse resistance, minimum physical properties, product assembly force (torque), product test pressures, critical product dimensions related to testing…
Publisher :
ISO
Status :
Withdrawn
Published Date :
2007-12-12
ICS Code(s) :
75.180.10
Graphic technology — Laboratory preparation test prints — Part 2: Liquid printing inks
ISO 2834-2:2007 specifies a test method for preparation of test prints produced with liquid water-based or solvent-based printing inks as used in flexography and gravure printing. These test prints are intended primarily for optical tests, such as colorimetry, transparency and reflection density as described in ISO 2846-3 and ISO 2846-5. They can also be used for testing gloss, light fastness and…
Publisher :
ISO
Status :
Withdrawn
Published Date :
2007-12-05
ICS Code(s) :
87.080
Measurement of radioactivity in the environment — Soil — Part 3: Measurement of gamma-emitting radio...
ISO 18589-3:2007 specifies the identification and the measurement of the activity in soils of a large number of gamma-emitting radionuclides using gamma spectrometry. This non-destructive method, applicable to large-volume samples (up to about 3 000 cm3), covers the determination in a single measurement of all the g-emitters present for which the photon energy is between 5 keV and 3 MeV. ISO…
Publisher :
ISO
Status :
Withdrawn
Published Date :
2007-12-02
ICS Code(s) :
13.080.01; 17.240
Measurement of radioactivity in the environment — Soil — Part 2: Guidance for the selection of the s...
ISO 18589-2:2007 specifies the general requirements, based on ISO 11074 and ISO/IEC 17025, for all steps in the planning (desk study and area reconnaissance) of the sampling and the preparation of samples for testing. It includes the selection of the sampling strategy, the outline of the sampling plan, the presentation of general sampling methods and equipment, as well as the methodology of the…
Publisher :
ISO
Status :
Withdrawn
Published Date :
2007-12-02
ICS Code(s) :
13.080.01; 17.240
Safety Requirements for Electrical Equipment for Measurement, Control and Laboratory Use - Part 2-04...
This National Standard of Canada is equivalent to International Standard CEI/IEC 61010-2-040:2005. 1 Scope and object This clause of Part 1 is applicable except as follows: 1.1.1 Equipment included in scope Replacement: This International Standard specifies safety requirements for electrical equipment intended for sterilization, washing, and disinfection of medical materials in the medical,…
Publisher :
CSA
Status :
Withdrawn
Published Date :
2007-11-30
ICS Code(s) :
19.080; 71.040.10