Wheelchairs — Part 11: Test dummies
ISO 7176-11:2012 specifies requirements for test dummies of any mass greater than or equal to 25 kg, to be used in the evaluation of wheelchairs. ISO 7176-11:2012 provides formulae that specify the location of the overall centre of mass of test dummies, the masses of the segments that comprise the test dummies and the locations of pivots that connect the segments. It also specifies the…
Publisher :
ISO
Status :
Published
Published Date :
2012-12-05
ICS Code(s) :
11.180.10
Household and similar electrical appliances — Safety —Part 2-5: Particular requirements for dishwash...
1 Scope [Add the following] This Standard applies to the safety of such equipment designed and constructed for installation and use in accordance with the Rules of the Canadian Electrical Code, Part I. Products covered by the scope of this Standard are also subject to the requirements of CAN/CSA-C22.2 No. 0. [Add a third dashed item to NOTE 101] – this Standard applies to both cord-…
Publisher :
CSA
Status :
Withdrawn
Published Date :
2012-11-30
ICS Code(s) :
97.040.40; 13.120
Solid-state lighting controls
Scope 1.1 This Standard applies to solid-state lighting controls rated at 600 V and less, with or without an integral switching (disconnecting) device, designed to be used in circuits (a) for the control of incandescent lamps; and (b) for the control of fluorescent, HID, ballasted, and similar lamps intended for installation in accordance with the Rules of the Canadian Electrical Code, Part I…
Publisher :
CSA
Status :
Withdrawn
Published Date :
2012-11-30
ICS Code(s) :
29.140; 29.140
Press-connect metallic fittings for use in fuel gas distribution systems
Scope 1.1 This standard applies to metallic (copper, steel and stainless steel) press-connect type fittings, and valves (hereafter referred to as fittings unless otherwise specified) for use with fuel gas systems intended for installation above ground, below ground, indoors and outdoors. 1.2 This standard applies to fuel gas systems rated for operating pressures not exceeding 125 psi (862…
Publisher :
CSA
Status :
Withdrawn
Published Date :
2012-11-30
ICS Code(s) :
75.200
Self-ballasted lamps and lamp adapters (Tri-national standard, with UL 1993 and NMX-J-578/1-ANCE)
Scope 1.1 These requirements are intended to cover both self-ballasted lamps and self-ballasted lamp adapters rated 120 to 347 V AC nominal for connection to screw-base, pin-base, or recessed single contact (RSC or R7) lampholders. These devices are intended for use in accordance with the National Electrical Code, ANSI/NFPA 70, and the Canadian Electrical Code, Part I, in non-hazardous locations…
Publisher :
CSA
Status :
Withdrawn
Published Date :
2012-11-30
ICS Code(s) :
29.140; 29.140
Gas cylinders — Compilation of national and international valve stem/gas cylinder neck threads and t...
ISO/TR 11364:2012 lists the different valve stem to gas cylinder connection threads currently and historically existing worldwide and provides official coded designations for them. These coded designations will then be available for identification and marking purposes. It also gives guidance concerning which threads are dimensionally identical and which are interchangeable. Furthermore, it…
Publisher :
ISO
Status :
Withdrawn
Published Date :
2012-11-29
ICS Code(s) :
23.020.35
Power line communication systems for power utility applications - Part 1: Planning of analogue and d...
IEC 62488-1:2012 applies to the planning of analogue and digital power line carrier systems operating over EHV/HV/MV electricity grids. The object of this standard is to establish the planning of the services and performance parameters for the operational requirements to transmit and receive data efficiently over power networks. The transmission media used by the different electricity supply…
Publisher :
IEC
Status :
Published
Published Date :
2012-11-28
ICS Code(s) :
33.200
Systèmes de communication sur lignes d'énergie pour les applications des compagnies d'élec...
La CEI 62488-1:2012 s'applique à la conception des systèmes à courants porteurs de lignes d'énergie analogiques et numériques fonctionnant sur des réseaux d'électricité EHT/HT/MT. Elle a pour objet de définir la conception des services et des paramètres de performance relatifs aux exigences opérationnelles en matière d'émission et de réception efficace des données sur les…
Publisher :
IEC
Status :
Published
Published Date :
2012-11-28
ICS Code(s) :
33.200
Gaseous hydrogen land vehicle refuelling connection devices
ISO 17268:2012 defines the design, safety and operation characteristics of gaseous hydrogen land vehicle (GHLV) refuelling connectors consisting of, as applicable, a receptacle and a protective cap (mounted on vehicle), and a nozzle. It applies to refuelling connectors which have working pressures of 11 MPa, 25 MPa, 35 MPa and 70 MPa, referred to as H11 - 11 MPa at 15 °C, H25 - 25 MPa at 15 °C,…
Publisher :
ISO
Status :
Withdrawn
Published Date :
2012-11-26
ICS Code(s) :
43.180; 71.100.20
Agricultural irrigation equipment — Thermoplastic collapsible hoses for irrigation — Specifications ...
ISO 16438:2012 specifies requirements and test methods for reinforced and non-reinforced thermoplastic collapsible hoses, which are intended to be used as main and sub-main supply lines for the conveyance and distribution of water for irrigation at water temperatures up to 50 °C. It is applicable to irrigation hoses with nominal diameters between 40 mm and 500 mm and working pressures between 0,3…
Publisher :
ISO
Status :
Withdrawn
Published Date :
2012-11-22
ICS Code(s) :