Road vehicles — Calibration fluids for diesel injection equipment
ISO 4113:2010 specifies the requirements for calibration fluids, i.e. a basic fluid and a closer value (CV) fluid, intended for testing and calibrating diesel fuel injection equipment in production, in service and in laboratories. The CV calibration fluid requires a closer tolerance range for kinematic viscosity and density, and can be specified to enhance the accuracy of the calibration setting…
Passenger car tyres — Verifying tyre capabilities — Laboratory test methods
ISO 10191:2010 specifies test methods for verifying the capabilities of tyres for passenger cars. Of the test methods presented, it is possible that only some will be required depending on the type of tyre to be tested. The tests are carried out in a laboratory under controlled conditions.
ISO 10191:2010 includes a strength test for assessing the capability of the tyre structure, with respect to…
Electromagnetic compatibility (EMC) - Part 6-1: Generic standards - Immunity for residential, commer...
This National Standard of Canada is equivalent to International Standard CEI/IEC 61000-6-1:2005.
1 Scope and object
This part of IEC 61000 for EMC immunity requirements applies to electrical and electronic apparatus intended for use in residential, commercial and light-industrial environments. Immunity requirements in the frequency range 0 Hz to 400 GHz are covered. No tests need to be…
Handling of waste materials in health care facilities and veterinary health care facilities
1 Scope
1.1
This Standard specifies requirements for the packaging, collection, handling, storage, and on-site
treatment and disposal of waste materials within health care facilities and veterinary health care facilities.
1.2
This Standard applies to health care facilities and veterinary health care facilities.
Note: This Standard may also be applied to the following:
(a) medical…
Plume scavenging in surgical, diagnostic, therapeutic, and aesthetic settings
1 Scope
1.1
This Standard applies to systems and equipment used to capture and evacuate plume. It applies to all settings where such systems and equipment are used, including, but not limited to, the following:
(a) surgical facilities;
(b) dental clinics;
(c) medical offices;
(d) veterinary facilities;
(e) laboratories and other research and testing facilities;
(f) cosmetic treatment facilities…
Recommendations for small renewable energy and hybrid systems for rural electrification - Part 9-6: ...
IEC 62257-9-6:2008(E) proposes a simple selection procedure and cheap, comparative tests which can be performed in laboratories of developing countries, in order to identify the most suitable model of small Photovoltaic Individual Electrification Systems (PV- IES) up to 500 Wp for a particular rural electrification project from a number of products submitted for test. The tests provided in IEC…
THIS STANDARD SUPERSEDES PART B45.1-02 of B45 SERIES-02.
1 Scope
1.1
This Standard covers vitreous and non-vitreous china plumbing fixtures and specifies requirements for materials, construction, performance, testing, and markings. This Standard#s performance requirements and test procedures apply to all types of water closets and urinals that discharge into gravity drainage systems in…
THIS STANDARD SUPERSEDES PART B45.4-02 of B45 SERIES-02.
1 Scope
1.1
This Standard covers plumbing fixtures made of stainless steel alloys and specifies requirements for materials, construction, performance, testing, and markings.
Note: The term #corrosion-resisting steel# is also applied to stainless steel.
1.2
This Standard covers the following plumbing fixtures:
(a) bathtubs;
(…
Hydraulic fluid power — Monitoring the level of particulate contamination of the fluid — Part 3: Use...
ISO 21018-3:2008 specifies a method for the semi-quantitative determination of the particulate contamination level using the filter blockage technique (also known as the mesh-obscuration method or the pore-blockage technique) either on-line or off-line in containers. ISO 21018-3:2008 also defines procedures for calibrating the instruments and verifying their correct operation both in the…
Health informatics — Point-of-care medical device communication — Part 90101: Analytical instruments...
ISO 11073-90101:2008 establishes a set of specifications to allow seamless multivendor interoperability and communication between point-of-care devices, data concentrators, and clinical information systems. CLSI document POCT1 provides the framework for engineers to design devices, workstations and interfaces that allow multiple types and brands of point-of-care devices to communicate…