Fibre optic active components and devices - Test and measurement procedures - Part 3: Optical power ...
IEC 62150-3:2015 It has been found that some optical transceivers and receptacles are susceptible to fibre optic cable induced stress when side forces are applied to the mated cable-connector assembly, resulting in variations in the transmitted optical power. The purpose of this part of IEC 62150 is to define physical stress tests to ensure that such optical connections (cable and receptacle) can…
Photovoltaic concentrators (CPV) - Performance testing - Part 2: Energy measurement
IEC 62670-2:2015 specifies the minimum requirements for determining the energy output and performance ratio for CPV modules, arrays, assemblies and power plants using an on-sun, measurement based method. This International Standard is intended to define testing methods, to establish a standard energy measurement for CPV modules, arrays, assemblies and power plants, and to specify the minimum…
Fibre optic active components and devices - Test and measurement procedures - Part 3: Optical power ...
IEC 62150-3:2015 It has been found that some optical transceivers and receptacles are susceptible to fibre optic cable induced stress when side forces are applied to the mated cable-connector assembly, resulting in variations in the transmitted optical power. The purpose of this part of IEC 62150 is to define physical stress tests to ensure that such optical connections (cable and receptacle) can…
Biomimetics — Terminology, concepts and methodology
ISO 18458:2015 provides a framework for the terminology on biomimetics in scientific, industrial, and educational purposes.
ISO 18458:2015 is intended to provide a suitable framework for biomimetic applications. The field of biomimetics is classified and defined, numerous terms are described, and a description of the process of applying biomimetic methods from the development of new ideas to the…
Smart community infrastructures — Principles and requirements for performance metrics
ISO/TS 37151:2015 gives principles and specifies requirements for the
· definition,
· identification,
· optimization, and
· harmonization
of community infrastructure performance metrics, and gives recommendations for analysis, including
· smartness,
· interoperability,
· synergy,
· resilience,
· safety, and
· security…
Petroleum and natural gas industries — Drilling and production equipment — Part 1: Electric submersi...
ISO 15551-1:2015 provides requirements for the design, design verification and validation, manufacturing and data control, performance ratings, functional evaluations, handling, and storage of tubing-deployed electrical submersible pump (ESP) systems as defined herein. This part of ISO 15551 is applicable to those components meeting the definition of centrifugal pumps including gas handling…
Optical amplifiers - Test methods - Part 4-3: Power transient parameters - Single channel optical am...
IEC 61290-4-3:2015(E) applies to output power controlled optically amplified, elementary sub-systems. It applies to optical fibre amplifiers (OFA) using active fibres containing rare-earth dopants, presently commercially available, as indicated in IEC 61291-1, as well as alternative optical amplifiers that can be used for single channel output power controlled operation, such as semiconductor…
1.1
Scope and references
This Standard details mechanical, physical, and electrical requirements for a newly manufactured
appliance that dispenses natural gas for vehicles directly into the vehicle natural gas fuel storage
system, referred to as a residential fueling appliance (RFA).
1.2
These requirements apply to appliances for:
a) natural gas only (see Clause 1.1);
b) outdoor or indoor…
1.1
This Standard applies to the lines and equipment associated with underground electric supply and communication systems located entirely outside buildings and fenced supply stations.
This Standard, which forms part of the Canadian Electrical Code, Part III, covers the requirements for construction of underground systems and includes electric supply and communication circuits that are…
1.1
This Standard applies to fans and ventilation equipment that is
a)
cord-connected, rated at not more than 250 V;
b)
permanently-connected to supply circuits of 600 V and less, single-phase or three-phase;
c)
used in non-hazardous locations;
d)
used in household, commercial, agricultural, or industrial locations;
e)
used indoors or outdoors; and
f)
used in accordance with the…