Flameproof non-rail-bound dieselpowered machines for use in gassy underground coal mines
1.1
This Standard describes the technical requirements and procedures necessary for the design,
performance, and testing of new or unused flameproof, non-rail-bound diesel-powered, self-propelled
machines for use in gassy underground mines.
Note: The working environment of gassy mines is characterized by the presence of methane gas and combustible
dust.
1.2
This Standard applies to…
Non-rail-bound diesel-powered machines for use in non-gassy underground mines
1.1
This Standard describes the technical requirements and procedures necessary for the design,
performance and testing of new or unused non-rail-bound, diesel-powered, self-propelled machines for
use in non-gassy underground mines.
1.2
This Standard applies to machines of 45 000 kg mass or less, which are designed to operate on level
ground at a maximum speed of 32 km/h or less.
1.3…
1.1 General
This Standard details mechanical, physical, and electrical requirements for a newly manufactured
appliance that dispenses natural gas for vehicles directly into the vehicle natural gas fuel storage
system, referred to as a residential fueling appliance (RFA).
1.2 Application
These requirements apply to appliances:
a) for natural gas only (see Clause 1.1);
b) for outdoor or…
1.1
This Standard applies to modular wiring systems combined with the office furniture in which they are intended to be used.
1.2
This Standard applies to equipment intended to be permanently connected to one or more supply circuits at a nominal system voltage of 120 V to ground, and a rating of 15 or 20 A maximum per circuit, for use in nonhazardous locations, in accordance with the Rules of…
1.1
This Standard applies to a Type FCC under-carpet wiring system utilizing cable that is installed under carpet squares that are removable, and associated accessories, intended for use in accordance with the Rules of the Canadian Electrical Code, Part I.
1.2
In this Standard, “shall” is used to express a requirement, i.e., a provision that the user is obliged to satisfy in order to comply…
Plumbing fittings incorporating electrical and/or electronic features
1.1
This Standard applies to plumbing products with electrical features rated not more than 150 V to ground. The equipment specified in this Standard is intended for installation in accordance with CSA C22.1 Canadian Electrical Code, Part I.
1.2
In this Standard, “shall” is used to express a requirement, i.e., a provision that the user is obliged to satisfy in order to comply with the standard…
Energy efficiency of high-intensity discharge (HID) and low-pressure sodium (LPS) lamp ballasts
1.1
This Standard applies to all ballasts for high-intensity discharge (HID) and low-pressure sodium (LPS)
lamps intended to operate with an input line frequency of 60 Hz.
Note: Safety requirements for ballasts are provided in Part 2 of CAN/CSA-C22.2 No. 74.
1.2
This Standard defines the measurement technique for determining the efficiency of HID and LPS lamp
ballasts for use in HID and LPS…
Fuel gas piping systems using corrugated stainless steel tubing
1.1
This Standard applies to fuel gas piping systems using corrugated stainless steel tubing (CSST), intended
for installation in residential, commercial or industrial buildings, and including the following
components as a minimum:
a) Corrugated stainless steel tubing (CSST);
b) Fittings for connection to the CSST; and
c) Striker plates (see Clause 3, Definitions) to protect the installed…
1.1
This Standard specifies the design, installation, operation and maintenance of site-built and modular
gaseous hydrogen fueling stations (HFS) for light duty vehicles, where light duty vehicles are defined by
the Environmental Protection Agency as passenger cars and light trucks, minivans, passenger vans,
pickup trucks, and sport-utility vehicles, also referred to as the “common category”…
Chemical sterilization of reusable medical devices in health care settings
1.1
This Standard specifies essential elements for using chemical processes to sterilize medical devices in
health care settings, with the object of achieving an adequate level of sterility assurance and minimizing
the risk of injury to health care setting personnel and patients.
Note: The term “health care setting” includes, but is not limited to, hospitals, free standing surgical centres,…