1 Scope
1.1 This Standard sets forth methods for both new installation and replacement installation of factory assembled windows, exterior doors, and skylights that are intended for installation in low-rise buildings and buildings used primarily for, but not limited to, residential occupancy where the windows, doors, and skylights (including window wall) are R, LC, or CW class within the…
1 Scope
1.1
Except as indicated in Clause 1.2, Part 1 of this Standard applies to all boilers, pressure vessels, pressure piping, and fittings, as provided for by the Act (as defined in Clause 3) and identified in Part 1 of this Standard. Notes: 1) It is possible that the size limitations specified in provincial or territorial statutes or regulations will differ from those specified in Part…
Industrial gas-fired natural draft heaters for installation in non-hazardous and hazardous location...
1 Scope
1.1 CSA/ANSI 3.21, Industrial gas-fired natural draft heaters for installation in non-hazardous and hazardous locations in oil and gas process applications, is arranged in two parts: a) CSA/ANSI 3.21, Part 1, covers industrial gas-fired natural draft heaters for installation in non- hazardous locations in oil and gas process applications; and b) CSA/ANSI 3.21, Part 2, covers…
1 Scope
1.1 General This Standard specifies requirements for the design, manufacture, construction, modification, operation, inspection, testing, and maintenance of passenger ropeways and passenger conveyors. Requirements for abnormal or unusual conditions are not specifically provided for, nor are all details of engineering and construction prescribed. It is intended that all work performed…
1 Scope
1.1 General This Standard specifies requirements for the design, performance, testing, marking, and instructions of manufactured free-standing guardrails that rely on mass and friction and that are intended to protect workers from a fall hazard. These guardrails are not fixed to a structure.
1.2 Exclusions This Standard does not apply to a) warning lines used for control zones; b…
Safe use of electrosurgical medical devices and systems in health care
1 Scope
1.1 This Standard deals with the following subjects: a) the use of electrical surgical units (ESUs) — medical devices and systems for the application of electrosurgical energy; b) training for the use of ESUs; and c) the installation of ESUs in any health care facility (HCF), as defined in Clause 3.
1.2 This Standard provides requirements for the education, training, purchasing,…
This document specifies the metrological characteristics of areal instruments for measuring surface topography. Because surface profiles can be extracted from surface topography images, most of the terms defined in this document can also be applied to profiling measurements.
Information technology for learning, education, and training - Learner mobility achievement informat...
This document defines a model for the recording and exchange of learner achievement information among student information systems (SIS) (also known as student management information systems), as well as the aggregation of information by third party suppliers.
In addition, this document defines refinements to the learner mobility achievement award (LMAI) model for representing the digital diploma…
Cranes — Limiting and indicating devices — Part 3: Tower cranes
This document gives requirements specific to tower cranes for limiting and indicating devices. It is applicable to tower cranes as defined in ISO 4306‑3.
It is not applicable to end stops such as buffers used to stop trolleying, travelling or luffing movements, nor to erection, dismantling operations or the changing of a crane's configuration.
NOTE General requirements for the devices…